Polar Refrigeration GF489 Manual Del Usuario página 8

Tabla de contenido

Publicidad

UK
Changing the Parameter Settings
1. Press
and
2. Press button
3. Press button
4. Once parameter is changed wait 6 seconds to return to normal working mode
5. To lock parameters press button
locked, they can be read, but cannot be modified.
6. To unlock parameters press button
Parameters Function
E1
Temperature to be controlled for slush
of Bowl One
E2
Temperature to be controlled for slush
of Bowl two (if fitted)
E3
Temperature to be controlled for slush
of Bowl three (if fitted)
F1
Temperature to be controlled for cold
beverage of Bowl One
F2
Temperature to be controlled for cold
beverage of Bowl Two (if fitted)
F3
Temperature to be controlled for cold
beverage of Bowl Three (If fitted)
C1
Probe correction for Bowl One
C2
Probe correction for Bowl Two
C3
Probe correction for Bowl Three
C4
Time Delay
C5
Temperature Contrast
CF
Temperature Unit
All manuals and user guides at all-guides.com
for three seconds to enter parameter setting mode. "E1" will flash.
to until desired parameter to change is displayed.
or
to increase / decrease value of the parameter.
and
and
till the code "888" flashes. Once the parameters are
until the code "ON" flashes.
Range
-10 to +10℃/14℉ to
+50℉
-10 to +10℃/14℉ to
+50℉
-10 to +10℃/14℉ to
+50℉
-10 to +10℃/14℉ to
+50℉
-10 to +10℃/14℉ to
+50℉
-10 to +10℃/14℉ to
+50℉
-10 to 10℃/-18℉ to 18℉
-10 to 10℃/-18℉ to 18℉
-10 to 10℃/-18℉ to 18℉
0-10 mins
-10 to 10℃/-18℉ to 18℉
℃ / ℉
Factory
Settings
-6⁰C/22F⁰
-6⁰C/22F⁰
-6⁰C/22F⁰
1⁰C /33.8F⁰
1⁰C /33.8F⁰
1⁰C /33.8F⁰
0⁰C /0F⁰
0⁰C /0F⁰
0⁰C /0F⁰
2mins
3⁰C
As desired

Publicidad

Tabla de contenido
loading

Tabla de contenido