Control Panel - Airrex HSCO-14 Manual De Operación Y Manual De Partes

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instruction & Parts Manual
OPERATION

CONTROL PANEL

Room : If the LED is On, the displayed temperature is for Room temp. If the LED is Off, the displayed
temperature is for spot temp.
Comp. : When the compressor is operating, the LED is On.
Error : Error signal ( E1 : High Pressure, E2 : Low Pressure, E3 : Sensor, AF: EVA Freezing, AL: Fire Alarm)
Water Full : Red light indicates 'Tank Full' . The compressor will shut off automatically.
Empty tank and replace in position to resume operation.
Align Drain Tank : The red light indicates the water tank is not in the correct position.
Display : Display Room/Spot temperature, and also the Setting Temp and Sleep Time if they had been set.
(Display of 'LO' : under the 32℉, Display of 'HI' : over the 99℉)
RUNNING & STOP
① ① Power : Use to power On / Off.
② ②
: Raises or lowers temperature and/ or sleep (off) time.
Cool : Use to select cooling mode.
Low Mode : Controls fan low speed.
High Mode : Controls fan high speed.
Off Timer : To set the length of time, once turned on,
that you wish the cooler to run for.
You can set 0~24 hours. Time intervals are
30mins. up to 10 hours and then 1 hour
between 10 and 24 hours.
1. START BY PRESSING THE ' ' POWER' ' BUTTON.
·Cooler will start up automatically.
·To STOP the unit, press the 'POWER' button once again.
2. To change fan speed, press the ' ' Low' ' button.
3. If you wish to operate on fan only, press the ' ' COOL' ' button.
To resume cooling, press the ' ' COOL' ' button again.
(Note : There is a 3 minute delay when switching functions to protect
the compressor)