Appliance Maintenance - Amano Pioneer Eclipse PE250AP Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN
Scheduled Maintenance
Operation
Interval
Replace Pre-Filter
Every 30 days or 600 hrs.
Replace Light Filter
Every 90 days or 1800 hrs.
Tighten UV-C Bulbs
Every 90 days or 1800 hrs
Replace HEPA Filter
Every year or 8,000 hrs.
Replace UVC-Bulbs
Every year or 8,000 hrs.
Replace filters more frequently in dusty or dirty environments.
1
2
Replace bulbs more frequently if appliance is commonly moved.
Pre-Filter Replacement
WARNING: Those replacing the Pre-Filter should wear
appropriate personal protective equipment, (PPE):
- A properly-fitted N95 or higher mask
- Eye protection, (safety glasses, goggles, or face shield)
- Disposable gloves
1. Make sure appliance is not plugged into a power
source.
2. Disconnect interconnect cord from the appliance's
cover.
3. Remove dirty Pre-Filter, secure in trash bag, and
dispose with regular trash.
4. Place new Pre-Filter over HEPA (Figure 5). Connect
interconnect cord. Device is now ready for operation.
Figure 5

Appliance Maintenance

1
WARNING: UV-C emitted from this device.
1
2
1
2
CAUTION: Do not operate device without filter and
cover securely attached.
1. Follow all safety guidelines and instructions for
removing Pre-Filter.
2. Make sure appliance is not plugged into a power
source and the interconnect cord is disconnected
from the appliance's cover.
3. Remove retaining screw from the cover. Note the
orientation of the cover
4. Remove the HEPA filter, secure in a trash bag,
and dispose with regular trash.
5. Place new HEPA filter (Figure 6) on unit base.
6. Carefully reposition cover over HEPA filter. Make
sure cover is oriented as previously installed and
bulbs are not contacting any surface.
7. Secure cover with retaining screw. Place new
Pre-Filter over HEPA filter.
8. Connect interconnect cord. Device is now ready
for operation.
WARNING: UV-C emitted from this device.
CAUTION: Do not operate device without filter and
cover securely attached.
1. Follow all safety guidelines and instructions for
removing Pre-Filter and HEPA filter.
8
HEPA Replacement
Figure 6
Light Filter Replacement