Methods Of Operation - Metabo HPT NR 83A5 Instrucciones Y Manual De Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

This metabo HPT nailer is equipped with a nailer
operation switching device.
Use SINGLE SEQUENTIAL ACTUATION MECHANISM or
CONTACT ACTUATION MECHANISM in accordance with
the work to be performed.
Explanation of the various nailing operations
SINGLE SEQUENTIAL ACTUATION MECHANISM:
First, press the push lever against the wood; next,
pull the trigger to drive the nail.
After nailing once, nailing will not be possible again
until the trigger is released and pressed again.
CONTACT ACTUATION MECHANISM: First, press
the push lever against the wood; next, pull the trigger
to drive the nail. Or,
pull the trigger; next, press the push lever against the
wood to drive the nail.
If the trigger is held back, a nail will be driven each
time the push lever is pressed against the wood.

METHODS OF OPERATION

This Nailer is equipped with the push lever and does
not operate unless the push lever is depressed (upward
position).
There are two methods of operation to drive nails with this
Nailer.
They are:
1. Intermittent operation (Trigger fi re):
2. Continuous operation (Push lever fi re):
How to Remove the Lock Pin
• When shipped, the tool's drive mode is locked
to
SINGLE
SEQUENTIAL
MECHANISM with the lock pin.
• By removing the lock pin as shown below, the tool
can be switched between SINGLE SEQUENTIAL
ACTUATION and CONTACT ACTUATION.
WARNING
When removing the lock pin, disconnect the
air hose from the tool and remove all nails.
Please be warned that the once the lock
pin is removed, the SINGLE SEQUENTIAL
ACTUATION and CONTACT ACTUATION
switch function will be activated.
000Book̲NR83A5̲US̲metabo.indb 19
000Book̲NR83A5̲US̲metabo.indb 19
• Use a pair of pliers like the one shown below to
pull o the lock pin.
CAUTION
The lock pin should be discarded after removal.
(1) Intermittent operation (Trigger fi re)
Use the SINGLE SEQUENTIAL ACTUATION
MECHANISM setting.
For intermittent operation, set the change
Rod as shown in the fi gure below. (i.e.
Set to SINGLE SEQUENTIAL ACTUATION
MECHANISM.)
To avoid double fi ring or accidental fi ring due
to recoil.
1) Set the switching device to SINGLE
SEQUENTIAL ACTUATION MECHANISM.
2) Pull the trigger rapidly and fi rmly.
ACTUATION
1 Follow the steps below to set up the SINGLE
SEQUENTIAL ACTUATION MECHANISM (as
shown in the diagrams that follow).
Disconnect the air hose and remove all nails.
Do not depress the push lever.
Do not apply any unnecessary pressure or
use any tools to move the switch.
Do not press the change stopper for any
other purpose other than to switch between
SINGLE
CONTACT ACTUATION.
1) If the lock pin is left, skip 2) through 3) and
proceed from 4).
English
Lock pin
WARNING
WARNING
SEQUENTIAL
ACTUATION
2018/05/22 13:58:56
2018/05/22 13:58:56
and
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hpt nr 83a5 sHpt nr 83aa5

Tabla de contenido