33856 EASYCLEAR 6000lv UI's(29-8-8)
8-X).
Warning! Ensure that the quartz tube is
assembled correctly so that it provides a
completely watertight seal.
Check the condition of the two o-rings on the
Quartz Tube Assembly (Fig 11-3). If these are
damaged in any way or you can not guarantee a
water tight seal, contact Hozelock Consumer
Services.
Biological Filter
Normally, there is no need to remove the
biomedia as any cleaning may kill the colonies of
bacteria that make toxic waste harmless.
1 - Remove the foam.
2 - The bag of Kaldnes Biomedia (Fig 7-U) can be
removed for cleaning.
3 - Wash in pond water.
4 - Reassemble the filter and restart.
Rotor Cleaning/Replacement
Follow the below procedure if the no water is
being pumped or flow is reduced:
1 - Release the Foam Cover by pushing the two
buttons (Fig 5-R) and lift the cover (Fig 6-S).
2 - Remove the foam (Fig 7-T), biomedia (Fig 7-U)
and stone bag.
3 – Turn the unit over and remove the 4 fixing
screws (Fig 10-AA) and lift the base clear.
4- Remove the 2 fixing screws (Fig 10-BB) and lift
the Pump Assembly clear.
5 - Twist the Pump Chamber anti-clockwise (Fig
10-CC) and lift clear. The rotor can now be pulled
out for cleaning or replacement ( Fig 10-DD).
Important! Take extra care so as to not drop any
of the small components. See Fig 10A for
assembly of the rotor.
6 - Reassemble the pump and 2 off fixing screws
(Fig 10-BB).
7 - Reroute the cable (Fig 10-EE).
8 - Reassemble the filter, and restart.
All Year Pump Care
A quick daily check should be carried out to
ensure that the pump is performing satisfactorily.
Once a week- Remove the outer casing and
Fountain Head in accordance with the general
maintenance notes. Depending on pond water
conditions, cleaning may be required more
frequently.
Once a year- Completely disassemble the unit
including the Rotor Assembly as described in the
29/8/08
All manuals and user guides at all-guides.com
14:16
Page 8
general maintenance notes, and wash all
components in clean, freshwater. Replace worn
or broken parts.
Winter Storage
When not in use, the unit should be removed,
thoroughly washed and cleaned, dried and
stored in a dry frost protected area. Always store
the unit with the foam and foam cover off to
ensure adequate ventilation and drying.
Spare Parts
(Refer to Fig 11). Contact the Consumer Services
Helpline on +44 (0)121 313 1122
1. Foam (single)
2. UV Lamp -
3. Quartz Tube Assembly
4. Pump rotor
5. Fountain and extension
segment bagged set
6. Transformer
Fish Stocking Rate and
Density
Under normal conditions, the EasyClear™ will
support up to 1.44m of fish. Introduce fish slowly
over the first few weeks, up to 20% of the
maximum recommended level, increasing to 50%
after six months. The balance will allow for fish
growth.
Clearwater Guarantee
We guarantee you Clearwater or your money
back!
This guarantee runs for 12 months after
purchase, provided that:
• You have followed the installation and
operating instructions
• You are using equipment of the correct size
and stocking level for your pond
• You consult our Helpline +44 (0)121 313 1122
early enough for any problems to be put right
• The product has been returned undamaged. A
refund can only be authorised by Hozelock
Cyprio and is made at the place of purchase.
3 Year Product Guarantee
If this unit, excluding the Rotor Assembly, Filter
Item Numbers
1408
1540
1556
1461
Z31785
Z13193