Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 44

TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to "HEAT & COOL MODEL".
In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the power
supply plug or turn off the circuit breaker, and consult authorized service personnel.
WARNING
Merely turning off the unitís power switch will not completely disconnect the unit from the power
source. Always be sure to disconnect the power supply plug or turn off your circuit breaker to ensure
that power is completely off.
Before requesting service, perform the following checks:
NORMAL
Doesn't operate imme-
FUNCTION
diately:
Noise is heard:
Smells:
Mist or steam are
emitted:
Airflow is weak or stops:
Water is produced from
the outdoor unit:
En-13
9379143004-03_OM_en.p65
Symptom
G If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.
G Whenever the power supply plug is disconnected and then recon-
nected to a power outlet, the protection circuit will operate for about
3 minutes, preventing unit operation during that period.
G During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner's piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).
G During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.
*G During Heating operation, a sizzling sound may be heard occa-
sionally. This sound is produced by the Automatic Defrosting
operation.
G Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.
G During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the air emitted from the air conditioner, resulting in
condensation and misting.
*G During Heating operation, the outdoor unit's fan may stop, and
steam may be seen rising from the unit. This is due to the Auto-
matic Defrosting operation.
*G When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.
*G During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat to a higher setting.
*G During Heating operation, the unit will temporarily stop opera-
tion (between 4 and 15 minutes) as the Automatic Defrosting mode
operates. During the Automatic Defrosting operation, the OPERA-
TION indicator lamp (green) will flash.
G The fan may operate at very low speed during Dry operation or
when the unit is monitoring the room's temperature.
G In the monitor AUTO operation, the fan will operate at very low
speed.
*G During Heating operation, water may be produced from the out-
door unit due to the Automatic Defrosting operation.
13
Problem
13/3/09, 10:05
See page
12
12
12
12

Publicidad

Tabla de contenido
loading

Tabla de contenido