EC Declaration of Conformity: as Chief Executive Officer of this company, the undersigned declares under its sole responsibility that the products described
EN
in this manual comply with the requirements of the following Directives and relevant standards and/or technical specifications:
1) EC Directive 1999/5/EC - R & TTE Directive - March 9, 1999 (in Italy Legislative Decree 05/09/2001 no. 269) regarding radio and telecommunications
terminal equipment and the mutual recognition of their conformity. The following Standards and/or technical specifications have been applied:
- LVD and health protection (art. 3(1)(a)): EN 60950-1 (2006-04), EN 50371 (2002-03)
- EMC (art. 3(1)(b)): EN 301 489-1 V1.8.1 (2008-04), EN 301 489-3 V1.4.1 (2002-08), EN 301 489-7 V1.3.1 (2005-11)
- Radio Spectrum (art. 3(2)): EN 300 220-1 V2.1.1 (2006-04), EN 300 220-2 V2.1.2 (2007-06)
In compliance with Annex 4 of aforementioned Directive, this is a Class 2 product and can therefore be placed in the market and put into service without restrictions.
2) EC 2004/108 Directive dated December 15, 2004 on the harmonization of the laws of the Member States relating to electromagnetic compatibility. The following
Standards and/or technical specifications have been applied: EN 50130-4 (1995-12) + A1 (1998-04) + A2 (2003-01) - EN 55024 (1998-09) +A1 (2001-10) + A2 (2003-
01) - EN 301489-1 V1.8.1 (2008-04) - EN 301489-3 V. 1.4.1 (2002-08) - EN 301489-7 V1.3.1 (2005-11).
3) EC 2006/95 Directive dated December 12, 2006 on the harmonization of the laws of the Member States relating to electrical equipment designed for use within
certain voltage limits. The EN 60950-1 (2006-049) Standard has been applied.
GENERAL WARNING - to be carefully complied with using the products in this manual (if applicable).
Please read carefully before operating the devices.
Installation: any installation, maintenance and/or change made to these control panels and to their accessory equipment must be performed by qualified technicians.
These operations may be subject to additional specific technical regulations to which the system must comply.
Electrical connections: connection to the 230VAC/50 Hz power supply must be made using the appropriate plug. This plug must be disconnected from the power
supply before the unit's housing may be opened.
Rechargeable batteries and/or any kind of battery: this device uses batteries which are dangerous to the public health as they are potentially harmful pollutants.
Replace battery only with correspondent models. Place and connect batteries according to the polarity supplied in the instructions. Used batteries must be disposed
of in compliance with current regulations, even when equipments are scrapped. They must therefore be removed from the devices before they are scrapped and be
returning to the equipment's supplier or deposited in the containers provided by the distribution network.
Responsibility: the manufacturer disclaims any liability resulting from an improper installation and/or maintenance, improper use and/or failure to use the supplied
equipment.
Warranty:
1) Guarantee is supplied in compliance with the Italian Law for a period of three years from manufacturing date; the expiry date stated on the equipment shall apply
for this purpose.
2) In compliance with current Italian regulations, the last retailer selling this product shall provide individual consumer guarantee (Italian Legislative Decree 2-2-02 24).
Copyright: Silentron S.p.a. reserves all rights to this manual. Total or partial reproduction of the text and images contained herein, as well as their publishing on the
web and/or public dissemination of the same by any other means is expressly forbidden.
Regulatory Compliance: in addition to what is described in the declaration of conformity, we hereby also state that:
- this is an Environmental Class 2 product - for indoor use - and a Class I product according to 300.220-1 (04 /2006) Standard.
Overview
Controller is a small table-top control panel equipped with a large touch screen that is used to control several intrusion detectors and alarm devices should an alarm
event occur.
Controller must be kept permanently connected to the mains power supply and uses back-up lithium batteries in the event of power failure. The large display shows
all of the information that the user needs to be able to use the system. It also supplies the information that the installer requires to setup the system as well as the
touch-sensitive buttons needed to perform such operations. "Controller" does not require wired connections and is easily and quickly installed since device and
alarm (event, tamper and supervision alerts) operations are managed over dual frequency radio transmissions that alert the user in real time of any new event.
Features and Operation. Controller receives the radio transmission sent by each setup detector and displays the detector's assigned name as well as any faults or
intrusion alarms on its display. The control panel manages the transmissions and enables its on-board buzzer sending signals to the alarm devices as follows.
Detectors or sensors. Controllers supports up to 32 Silentron wireless detectors which can be setup according to the required safety features.
The devices transmit their supervisory report, low battery alert and tamper alarm 24/7. Activity in the enabled zones will trigger an alarm when the control panel is
totally or partially armed. According to each detector's setup, the system will trigger either sound or voice alarms.
Alarm devices. Controller manages various kinds of outdoor sirens (Sirenya), buzzers and voice sounders (Hablo), devices reporting operating conditions and
alarms (Displayer), indoor sirens and RX receivers. Each of these devices will trigger a sound or voice (pre-recorded message) alarm according to its features and to
detectors' setup. All alarms last up to 3 minutes, they can be repeated and are stopped by disarming the control panel. There is no limit to the number of installable
alarm devices, but each device will take up one of the available 32 locations as if it were a detector when two-way tamper and low battery alert operations are
enabled.
Remote controls. Controller can be armed and disarmed using PCK HT remote controls (up to 8 different ones). See diagram.
Controller is fitted with an on-board buzzer that sounds together with the other alarm sounding devices when the system is armed. Only Controller's buzzer will
sound during 24/7 reporting when the system is disarmed. All alarm events are stored in the unit's memory and can be displayed using the device's keys.
Detectors can be setup to operate over two different zones, A and B, in order to be able to partially or total arm the system directly from the display. The white
button of the remote control arms A zone, while the red one arms both A and B zones. The remote control also features a the yellow button that can be setup to
arm only B zone (see remote controls' instruction manual). Successful arming is confirmed on the display and can be confirmed also by the unit's buzzer as well as
by setup alarm devices in the following manners: 3 beeps confirm total arming, one prolonged beep confirms partial arming while a distinctive single beep sounds
when the system is disarmed.
Positioning. Wall mounting is not foreseen since Controller is a "table top" device. The unit can be positioned inside furniture (not made with metal to avoid limiting
radio range) if you want to hide it from view. Caution! Controller uses not rechargeable batteries that come into operation in the event of power failure. The device
must be connected to the power supply at all times to ensure that batteries supply enough power.
Technical specifications (see also drawings):
Environmental Class: 2 - The device is to be used only indoors.
Power supply: 230 Vac 50Hz +15-10% 2,5W power use - Back up not-rechargeable lithium batteries (LS 14500): 2 AA 3.6V 2Ah.
Power consumption: 60mA on stand-by when the display is not lit - 100mA during transmission/reception.
Display: one large backlit display showing data that is not encrypted.
Radio and local alerts: supervisory report from external devices – tamper alarm (housing being opened) – low battery alert.
Radio transmission: the device features a microprocessor controlled self-learning management system with simultaneous dual-band digital radio transmission
coded at the factory - features and power supply comply with current regulations. Radio range: approximately 100m in open air without any background band noise.
Device's positioning and/or the area's radio band interference may significantly reduce indoor transmission range. You must always check radio range before final
installation.