GENERAL WARNING

This hood has been developed and produced in accordance with DS/
EN 60335-1.
This hood is only suitable for use in private households; any other
use will invalidate the warranty.
All installations must be carried out by a qualified technician in ac-
cordance with the instructions set out by Thermex Scandinavia A/S
(Thermex) and the Laws in force.
Thermex disclaims any liability for damage resulting from improper
installation, assembly, operation or incorrect settings.
BEFORE INSTALLATION/OPERATION
Check the hood for transport damage, defects and missing parts
immediately upon receipt.
Transport damage should be reported immediately to the transport
company and Thermex upon receipt.
Any defects and/or missing parts should be reported to Thermex
within 8 days of receipt and prior to installation/operation.
INSTALLATION
The hood is designed to operate at 230 volts ± 10% ~ 50 Hz in ac-
cordance with EN 50160
Connect the hood with the attached plug. NOTE: If the plug has an
Earth terminal, the hood MUST be earthed.
For models with an external motor it is important NOT to use com-
mon zero when installing the hood and motor, as this will affect
operation.
When using an external motor from another supplier, the motor
MUST be compatible with the selected hood. Failure to comply with
this will invalidate the warranty.
The hood must not be connected to the mains before installation is
complete.
The air must not be discharged from the hood into a pipe used for
extraction from devices using gas or other combustible materials.
Such devices must have a separate vent.
THERMEX VERTICAL ATOMATIC
The national legislation on air emissions must be observed.
Always use the original exhaust measurements. Reduction of the
exhaust size will reduce performance and increase sound levels.
The exhaust from the hood to the outside should be as short as
possible in order to maximise the efficiency of the hood.
The number of bends on the exhaust should be minimal in order to
maximise the efficiency of the hood.
Thermex recommends that vent hoses insulated against noise and
condensation for all bushings in unheated rooms are always used.
Thermex recommends using a silencer when flexible hoses are used
in order to minimise sound levels.
When using flexible hoses, always ensure that they have been fully
extended in order to minimise air resistance and thereby maximise
suction performance.
Different materials require different rawlplugs and screws. Rawl-
plugs and screws suitable for the material onto which the hood will
be mounted on must be used.
If the instructions for the installation of screws and fittings are not
followed, it may result in electrical shock.
The minimum distance to gas hobs from the burner's edge to the
underside of the hood MUST be a minimum of 65 cm in accordance
with EN 60335-2-31.
For cupboard-integrated, suspended and wall-mounted hoods,
Thermex recommends that the distance between the hob and cook-
er hood is between 50 cm and 70 cm in order to ensure maximum
suction.
Always check the minimum distance between the hob and the
cooker hood, as indicated in the instructions for the hob. The in-
structions for the hob MUST be observed if a greater distance than
that recommended by Thermex is indicated in this manual.
Thermex recommends that the distance between the hob and the
hood should not exceed 3 meters for ceiling-integrated models.