Spare parts see page 16
1.
hand shower
2.
support, assy
3.
hose 1,60 m
4.
upper cover
5.
flange
6.
body showers
7.
body showers
8.
handle
9.
handle for thermostat
10.
flange
11.
frontcover
Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice
versa, when mixer is closed
Spout temperature does not
correspond with temperature set
Temperature regulation not
possible
Safety stop button not operating
On/off control stiff
Test certificate
DVGW
27170000
18
Hansgrohe · Postfach 1145 · D-77761 Schiltach · Telefon +49 (0) 78 36/51-1282 · Telefax +49 (0) 7836/511440
28500000
97024000
28276000
97324000
97326000
28408000
28406000
10490000
38391000
97858000
97859000
Cause
-Supply pressure inadequate
-Regulator filter dirty
-Shower filter seal dirty
-Backflow preventers dirty or
leaking
-Thermostat has not been
adjusted
-Hot water temperature too low
-Temperature regulator dirty or
calcified
-Spring defective
-Button calcified
-On/off control insert defective,
calcified
P-IX
SVGW
PA-IX
18732/IOB
E-Mail: info@hansgrohe.com · Internet: www.hansgrohe.com
English
12.
sleeve
13.
adapter for handle
14.
thermostat cartridge
15.
nut
16.
cartridge on/off control
17.
sealing set
18.
connection hose
19.
fixing set for hose connection
20.
mounting set
21.
hose connection angel (2)
22.
non return valve
23.
filter
ACS
Remedy
-Check water pressure (If a pump
has been installed check to see if
the pump is working).
-Clean filters
-Clean filter seal between shower
and hose
-Clean backflow preventers,
exchange if necessary
-Adjust thermostat
-Increase hot water temperature
to 42 C to 65 C
-Clean temperature regulator,
exchange if necessary
-Clean spring and/or button,
exchange if necessary
-Clean spring and/or button,
exchange if necessary
-Replace on/off control insert
NF
WRAS
95032000
97108000
94282000
96945000
96645000
95037000
13099000
94158000
96179000
25967000
97350000
97973000
KIWA