Installation method
Warning
Use single-phase 220-240V power.
Using the incorrect power supply may cause fi res,
electric shocks or malfunctions.
Check
□ Single-phase 220-240V power is being used.
□ Make sure that a ground-fault circuit interrupter is installed in the fixed wiring.
□ A single wire (cable core: between 2.0mm
Make sure that a means for
disconnection is incorporated in the fixed
wiring in accordance with the wiring rules.
Follow the illustration on the right for the internal
wiring.
1
Fix the installation panel to the wall using
the 4 mounting screws.
The position illustrated on the right is
recommended.
Use commercially available screw anchors when
installing the appliance on a concrete wall.
Reinforce any walls made with materials other
than concrete before installation.
Leave a space of at least 130mm below
2
Cautions
the appliance.
Dirt or water sucked into the appliance
may damage it.
Do not install when the product (power cable) is
electrifi ed.
Doing so may result in electric shocks.
2
2
and 3.0mm
) is being used for the power cable.
Power cable
Conduit box
Power cable hole (rear face)
Appliance external shape
Appliance mounting screw
position
Mounting screws
(Included)
− 6 −
Caution
68
Terminal block
79.5 103.5
Unit (mm)
Installation
panel
Appliance shape
79.5 103.5
Appliance mounting
screw position
Unit (mm)
230
207
164
57.5
Recommended
installation heights
For men: 925mm
For women: 905mm
15.5
10
Detailed view of
installation holes
230
207
164
57.5
Recommended
installation heights
For men: 925mm