ENGLISH
oven (see the picture)
4- Reassemble the back of the oven
b- it is necessary to connect the oven's chimney to
the appropriate entry placed on the back side of
the hood by using the silicone tube supplied with
the hood. The silicone tube has to be tightened
to the oven's chimney by using the metallic clamp
(supplied also with the hood).
In case the hood is connected to only one
oven, the smoke entry that remains free must be
connected to the condensate drainage system
tube.
CONNECTION SECOND OVEN
In equipment with the hood there's a second oven-
hood connection cable : such a cable allows to
connect two ovens to same hood ( overlapped
ovens). The hood is indifferently controlled by the
first or the second oven. An extremity of the cable
goes connected to the hood's control card (connector
HOOD/SC2 CN5) while the other extremity goes
connected to second oven.
The chimney of the second oven goes connected to
the appropriate entry in the back side of the hood (the
silicone tube in order to connect the second oven is
supplied in equipment with the overlap's kit XC610).
4.3
WATER CONNECTION
CONNECTION TO THE WATER SYSTEM
It is necessary to place between the water system and
the hood an interception plug cock and a mechanical
filter. Before connecting the water pipe to the hood,
please let a certain quantity of water flow to clean any
eventual remainder. The incoming water should have
a nominal pressure value included between 0.5 and
2 bars.
CONNECTION OF THE CONDENSATE
DRAINAGE SYSTEM
The condensate drainage system is located on the
back side of the hood and goes connected with a
rigid or flexible tube and piped to an open drainage;
its diameter shouldn't be inferior to the one of the
drainage attack. Lock the tube by using the metallic
clamp so that the same tube does not extract from the
drainage.
Don't throttle the flexible conduits & avoid elbows
UNO
R
ENGLISH
ENGLISH
5