DESCRIPTION
The unit can be found in filtering hoods, exhaust hoods or in hoods with an outside motor. In the Filtering hoods (Fig. 1)
the air and steam taken up by the unit are purified with carbon filters and returned to the environment through the aeration
grids on the side of the flue. WARNING: When using filtering hoods, both carbon filters and an air deflector must be used.
Located in the upper part of the pipe, this deflector recycles the air to the environment (Fig. 1A). In the Exhaust hoods (Fig
.2) an exhaust duct conveys the steam and cooking odors directly outside through the wall/ceiling. Therefore they do not
require carbon filters. In the hoods with an outside motor (Fig. 3), a vacuum suction unit must be connected; this exhaust
will operate separately, conveying the exhaust air through the unit. Only use vacuum units suggested in the original
catalogue.
INSTALLATION
To facilitate installation, before starting remove the grease filter/s: press inward on the clamp at the handle and pull the
filter downward (Fig. 4/5).
Installation of a utensil holder (upon request): See Figure 6A or 6B depending on the model purchased. Install the utensil
holder with 4 flathead screws (supplied). Secure the 2 supports (C) to the hood, one on the left and one on the right; insert
the utensil holder into these supports. Keep a good grip on it until you have installed, and secured, at least one of the 2
supports (D) at the top of the hood.
Installation on the wall (Fig. 7): Using the special drilling template, drill the required holes in the wall. As previously
specified in the chapter "Warning" remember there must be a minimum of 650 mm between the bottom edge of the hood
and the stop of the stove. Secure the metal bracket (B) to the wall using the screws and plugs (bracket, screws and plugs
are all supplied with the unit). Use the 2 triangles cut into the bracket to position it precisely along the vertical axis of the
hood. Then set the hood onto the bracket. Adjust the horizontal position, shifting the hood to the right or left as needed
lining it up with the wall units. If the height of the hood also requires adjustment, use the special regulation screws (V)
(supplied). Once regulation has been completed, finish securing the hood with 4 more screws (M): mark the points for the
4 holes on the wall, remove the hood and drill (8mm diameter holes); then use the plugs and screws to complete installation.
Installation with rear panel (Fig. 8): The rear panel is positioned at the top of the stove, flush against the wall. Rest the
lower edge of the panel behind the stove and anchor the upper edge to the wall using the two holes found on the panel.
Insert the screws and plugs provided (A). The unit is secured to the rear panel as though it were being installed on the wall:
use the supplied metal bracket (B) and the screws and plugs supplied with the panel.
Securing the extension pipes: Basic installation requirements: – Set the electrical power supply within the space covered
by the decorative piping. – If your unit is installed in an Exhaust hood or in a hood with outside motor, prepare the air exhaust
hole.
When installing exhaust hoods and hoods with outside motor, to achieve the best possible conditions use an air exhaust
pipe that : i) is as short as possible, ii) has a minimum of curves (maximum angle: 90°), iii) is made of a material that
complies with the standards (which vary from nation to nation) and iv) is smooth on the inside. It is also advisable to avoid
any drastic changes in pipe section (diameter: 150 mm).
Adjust the width of the extension pipe support bracket (W) using screws A indicated in Fig. 9. Then use the plugs and
screws provided to secure it to the ceiling. Make certain it is aligned with the hood. For filtering hoods, the air exhaust grids
are positioned in the upper part (Fig. 10). For exhaust hoods, turn the upper pipe over so that the air exhaust grid is in the
lower section (Fig. 11).
Be very careful when handling the telescopic pipes, especially when resting these on the hood body, to
prevent scratching.
Exhaust hoods and hoods with outside motors: Connect the hood flange to the exhaust hole in the wall/ceiling using a
flexible pipe. Only for models with outside motor (Fig. 12): plug the hood into the outside control unit using the special
terminal block: remove wire clamp A and lid B from the wiring junction box. Secure the wire connecting the control unit
to terminal C. Then replace wire clamp A and lid B on the wiring junction box. The other end of the wire is secured to the
terminal block on the outside control unit. Plug in the hood. Insert the extension pipes setting them on the hood; extend
the upper pipe to the ceiling and secure with the 2 screws (G) - Fig. 13.
Filtering hood: Secure the deflector to the upper pipe using the 4 special screws (provided) – Fig. 14; hook up the flexible
pipe (diameter: 125) to the deflector. Install the reduction (provided) on the hood air outlet point (Fig. 15). Take the 2
assembled extension pipes and set them on the hood; extend the upper pipe to the ceiling and secure with the 2 screws
(G) - Fig. 13. Extend the lower pipe taping it in place and then connect the flexible pipe to the hood reduction. Plug in the
hood. Extend the lower pipe downward setting it against the hood. Install the carbon filters by pressing the 2 tabs on the
filter down into the special housing (Fig. 16) and rotating upward.
OPERATION
Depending on the model, the unit is equipped with the following commands:
Commands shown in Fig. 17: Button A = turns the lights on/off. Button B = turns the TIMER on/off: press once to turn
the timer on, therefore, after 5 minutes, the motor cuts out (at the same time the selected speed blinks on the display); the
timer remains on if the motor speed is changed. Display C = - indicates the selected motor speed (from 1 to 4); - indicates
Timer On when the number blinks; - indicates Filter Alarm when the central segments is on or blinking.