➤ Remove the safety caps on the positive terminal (+) and the negative ter-
minal (–).
NOTICE! Beware of damage
A
Make sure the polarity is correct when connecting the parking as-
sistance to the battery.
➤ Connect the connection cable for the parking assistance to the positive
terminal (+) and the negative terminal (–) of the battery using the battery
quick connection as an aid (fig. 6, page 4).
✓ The parking assistance is supplied with voltage and can be used. Ob-
serve the information in the operating manual for the parking assistance.
Connecting other consumer units
➤ Connect other consumer units, such as coolers, to the 12-V socket on the
device.
8.3
Checking the charging status
Without any connected consumer units (quick test)
➤ Ensure that the battery is not being charged.
➤ Press the test switch.
✓ The LEDs show the charging status:
Status LED
LED FULL lights up green
Both LEDs are off
LED LOW lights up red
With connected consumer units
➤ Ensure that the battery is not being charged.
➤ Connect a consumer unit to the battery.
➤ Ensure that the consumer unit is switched on.
➤ Press the test switch.
EN
Voltage
Charging status
>12.8 V
The battery is fully charged.
11.4 V – 12.7 V
The battery is partially charged.
<11.3 V
The battery is discharged.