NOTE: This tube can be achieve 0-10V dimming when installed in combination with dimming mate (Westing-
house Lighting model 502606930). One dimming mate only can work with one LED tube.
Wiring diagram:
WARNING
Warning: Risk of re or electric shock. LED retro t kit installation requires knowledge of luminaires electrical
systems. IF not qualifed, do not attempt installation. Contact a quali ed electrician.
Warning: Risk of re or electric shock. Install this kit only in the luminaires that have the construction features
and dimensions shown in the photographs and/or drawings and where the input rating of the retro t kit does
not exceed the input rating of the luminaire.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
WARNING- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other
sharp objects.
Installers should not disconnect existing wires from lampholder terminals to make new connections at
lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and
make new electrical connections to lampholder lead wires by employing applicable connectors.
THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE
COMBINATION SHALL BE DETERMINED BY UL OR AUTHORITES HAVE JURISDICTION.
The units covered by this report were intended to retro t surface mount with di user for these models, Type
IC or non-IC recessed mount listed uorescent luminaires that use maximum 2 tubular lamps, the minimum
lamp compartment dimensions are tabulated below:
MODEL NUMBER
LED 40T8/96"/DIM/XX Ballast Bypass
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
The luminaire wiring has now been modified and will no longer operate fluorescent lamps.
This device is not intended for use with emergency exits.
L
N
Dimming Mate
AC INPUT 120~277V
MINIMUM COMPARTMENT DIMENSIONS
[Length x Width x Height] [cm]/[in]
244 x 27 x 7 / 96.06 x 10.63 x 2.76
Suitable for damp locations.
RED
TYPE B LAMP
BLACK
PURPLE
0 ~ 10V Dimmer
GREY
4
LAMP
Lamp-to-Lamp
QUANTITY
Spacing (cm)