Test certificate
DVGW
13340XXX
X
13360XXX
X
Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice
versa, when mixer is closed
Spout temperature does not
correspond with temperature set
Temperature regulation not
possible
Shower or spout dripping
Instantaneous heater didn't work
with thermostat
6
All manuals and user guides at all-guides.com
P-IX
SVGW
PA-IX
X
8856/IDB
PA-IX
X
8856/IDB
Cause
-Supply pressure inadequate
-Filters are dirty
-Shower filter seal dirty
-Backflow preventers dirty or
leaking
-Thermostat has not been
adjusted
-Hot water temperature too low
-MTC-thermo cartridge calcified
-Dirt or sedimentation on valve
seat, shut-off unit damaged
-Ecostop ring not removed.
-Flow limiter in handshower isn't
removed
-Filters are dirty
-Non return valve hasn't moved
back
English
ACS
NF
WRAS
X
X
X
X
Remedy
-Check water pressure (If a pump
has been installed check to see if
the pump is working).
-Clean filter in front of the mixer
and on the MTC-thermo cartridge
-Clean filter seal between shower
and hose
-Clean backflow preventers,
exchange if necessary
-Adjust thermostat
-Increase hot water temperature
to 42 C to 65 C
-Exchange MTC-thermo cartridge
-Clean or exchange shut-off unit
-Remove ecostop ring (A)
-Remove flow limiter
-Clean the filter / exchange filter
-Exchange non return valves
KIWA
X
X