Tilting Discharge Device Replacement And Use; Single Plastic Bag Replacement And Use; At The End Of A Cleaning Session; Maintenance, Cleaning And Decontamination - Blastrac BDC3140 DB Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Instruction Manual BDC3140 DB/LP
Tilting discharge device replacement
and use
Figure 9
1.
Tilting discharge device assembly
Fasten the hopper to the filtering chamber, by inserting
it into the relevant housings and, operating on the lever
(2) to lock it (figure 9).
Insert the bag (Longopac
and fasten its end with the belt (1, figure 10).
Engage the tilting discharge device support to the
hopper by fastening it with the relevant pins (figure 9).
Remove the bag (Longopac
support platform and close its end with the supplied
clamp.
When the bag is full (Longopac
with two clamps by fastening them at 50 mm one
from the other, then with a pair of scissors cut the bag
between the two clamps (figure 10).
Single plastic bag replacement and
use
Figure 11
Place the plastic bag outside the tilting discharge device
support, taking care that the bag bottom lays on the lower
support platform and lock the upper part of the bag with the
belt.

At the end of a cleaning session

Turn off the vacuum cleaner and remove the plug from
the socket.
Wind the connection cable around the cable carrier
(Figure 12).
Empty the container as described in the "Emptying the
container" paragraph. Clean the vacuum cleaner as
described in the paragraph "Maintenance, cleaning and
decontamination".
Wash the container with clean water if aggressive
substances have been vacuumed.
Store the vacuum cleaner in a dry place, out of reach of
unauthorised people.
) into the relevant support
®
) until it lays on the lower
®
) close the upper end
®
Maintenance, cleaning and
decontamination
WARNING!
The precautions described below must be taken
during all the maintenance operations, including
cleaning and replacing of the filter.
To allow the user to carry out the maintenance
operations, the vacuum cleaner must be
disassembled, cleaned and overhauled as far as
is reasonably possible, without causing hazards
for the maintenance staff or other people. The
suitable precautions include decontamination
before disassembling the vacuum cleaner,
adequate filtered ventilation of the exhaust
air from the room in which it is disassembled,
cleaning of the maintenance area and suitable
personal protection.
Compartments that are not dust-tight must
be opened with suitable tools (screwdrivers,
wrenches, etc.) and thoroughly cleaned.
Carry out a technical inspection at least once
a year, e.g.: check the air filter to find out
whether the air-tightness of the vacuum
cleaner has been impaired in any way and
make sure that the electric control panel
operates correctly. This inspection must
be carried out by the manufacturer or by a
competent person.
Primary filter disassembly and
replacement
WARNING!
When the vacuum cleaner is used to vacuum
hazardous substances, the filters become
contaminated, therefore:
Work with care and avoid spilling the
vacuumed dust and/or material.
Place the disassembled and/or replaced filter
in a sealed plastic bag.
Close it hermetically.
Dispose of the filter in accordance with the
laws in force.
WARNING!
Filter replacement is a serious matter. The filter
must be replaced with one of identical filtering
surface characteristics.
Otherwise the vacuum cleaner will not operate
correctly.
www.blastrac.eu ‒ info@blastrac.eu
9/16
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bdc3140 lp

Tabla de contenido