Modello - Modèle - Model
Modell - Modelo
Fabbricante - Constructeur
Manufacturer - Hersteller
Fabricante
TRANSLATION OF ORIGINAL INSTRUCTIONS
WARNING! Do not damage the refrigerant circuit.
WARNING! Do not damage the inner or outer walls of the appliance: the refrigerant
fluid circuit may be damaged. In case of damage to the walls, do not start the appliance
and contact a qualified service technician.
WARNING! This appliance must only be installed by suitably qualified personnel in
order to reduce the risks connected with flammability.
WARNING! Keep the ventilation openings in the appliance casing or in the recessed
structure clear of obstructions.
WARNING! Never use mechanical devices or any other means to accelerate the
defrosting process, other than those recommended by the manufacturer.
WARNING! Do not use electrical appliances inside the compartments of the appliance
for storing frozen foods if these are not those recommended by the manufacturer.
Isobutane is a natural gas that doesn't affect the environment but is
inflammable. It is therefore essential to ensure that all refrigerant pipes are
not damaged before connecting the appliance to the mains supply.
Every 8 gr. Of refrigerant, the installation room must have a 1 m³ minimum
volume. The amount of refrigerant of the appliance is indicated on the rating plate
of the device. In the event of leakage of the refrigerant, avoid using open flames or
sources of ignition in the vicinity of the area of the leak. Be careful not to not damage
the refrigerant circuit pipes during positioning, installation and cleaning.
AVOID USING NAKED FLAMES OR SPARKS INSIDE THE APPLIANCE.
IN THE EVENT OF DAMAGE:
•
Keep the appliance far from flames or ignition sources.
•
Ventilate the room well for a few minutes.
•
Switch off the equipment, remove the power supply plug.
•
Inform customer service.
•
The higher the refrigerant content in the equipment, the larger the room must be hosting the equipment.
•
In rooms that are too small, a mix of flammable air and gas can form in the event of a leak.
• ALWAYS KEEP THE INSTRUCTIONS MANUAL SAFE AND IF THE APPLIANCE IS
SOLD, HAND IT OVER TO THE NEW OWNER.
• THE UNIT MUST NEITHER BE EXPOSED OR USED OUTSIDE OF THE POINT OF
SALE. IT MUST BE SHELTERED FROM WEATHER CONDITIONS. THE UPPER PART
OF THE APPLIANCE MUST REMAIN FREE.
• DO NOT EVER TOUCH OR HANDLE THE APPLIANCE WITH BARE FEET OR WITH
WET HANDS AND FEET.
• AFTER INSTALLING THE APPLIANCE MAKE SURE THAT IT IS NOT POSITIONED
ON THE POWER CABLE.
• TO DISCONNECT THE APPLIANCE FROM THE MAINS, TAKE OUT THE PLUG. DO
NOT PULL THE POWER CABLE OUT OF IT.
CORAL 118 WINE COOLER
EPTA S.p.A. - Sede legale
Via Mecenate, 86 - 20138 Milano – Italy
Capitale € 68.515.000 - R.E.A./MI – 1730229
Registro delle Imprese e Cod.Fiscale n. 04160730968
Partita IVA 04160730968
ENGLISH
SAFETY ADVICE
1 0 / 4 4
PAGE
N° DOC