Descargar Imprimir esta página

SEA CCT 440 Manual De Instalación Y Programación página 27

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

 
3
Product technical specification
Dimensions
 Container 90x90x115 (terminal board included)
 Front panel 96x96 mm
 Weight 0.5 kg
 Container made of self-extinguishing ABS
Power supplies
Field operation guaranteed:
 Maximum values 24÷240±10% V (DC)
 Maximum values 24÷240±10% V (AC), frequency from 30 to 440 Hz
 The polarity of connections can be inverted; it is not fundamental for the power supply system
(see terminals 40 and 42).
 Electrical wiring on removable terminal boards
Inlets
Temperature detection and control with Pt100 SEA-type sensors from -10 to +200°C
Outlets
Power supply type
Alternating current
Direct current
Features
 Access to the power unit programming directly from the front panel.
 Possibility to independently select each single channel.
 Possibility to use probes.
Performances
For all models CCT 440 – CCT 441 – CCT 442
 Construction in compliance with standards EN 61000-3-2, EN 61000-3-3, EN 61000-4-3, EN
61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8
 Possibility to independently select each single channel
 Possibility to use probes to maintain the environment temperature constant
 Inlet filter against interferences according to EN 61000-6-2:2005 standard
 Precision of ±1°C in the range from +30 to +150°C ±1 digit
 Management of cooling blower on all the probes
S.E.A. Società Elettromeccanica Arzignanese S.p.A.
 
Maximum voltage
250 V
110 V
30 V
27
ENGLISH
Maximum current
5 A
0.4 A
5 A
Load type
resistive
Page 3 of 25

Publicidad

loading

Este manual también es adecuado para:

Cct 441Cct 442