Installation of Indoor Unit

1. Mounting
plate should be installed horizontally. As the water tray's outlet for the indoor unit is two-way
type, during installation, the indoor unit should slightly slant to water tray's outlet for smooth drainage of
condensate.
2. Fix the mounting plate on the wall with screws.
3. Be sure that the mounting plate has been fixed firmly enough to withstand about 60 kg. Meanwhile, the
weight should be evenly shared by each screw.
18K UNIT:
24K UNIT:
1.Slant the piping hole (Φ55/70) on the wall slightly downward to the
outdoor side.
2.Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
1.
Connect the drain hose to the outlet pipe of the indoor unit .
Bind the joint with rubber belt.
2.
Put the drain hose into insulating tube.
All manuals and user guides at all-guides.com
Installation of Mounting Plate
694
52
82
14
940
139
685
Φ70
36
90
Drill Piping Hole

Installation of Drain Hose

- 22 -
194
160
Fig.5
184
Φ70
65
Indoor
Wall pipe
outlet pipe of
drain hose
indoor unit
rubber belt
outlet pipe of
drain hose
indoor unit
rubber belt
insulating tube
Outdoor
Seal pad
Φ
55/70
outlet pipe of
indoor unit