Wiring Power Input
User-Configurable Switches
PWR or RPS "DIP ON": When there is a power loss, the switch will
operate as "Relay ON". If connecting only to single power source and a
power loss occurs, the switch system will shut down and not operate as
"Relay ON".
Port 1~ Port X: "DIP ON": If the port link is down, the switch will operate
as "Relay ON". In doing so, it can help to inform when link-down events
occur.
It is not required to connect alarm equipment to the Alarm Relay output
port. An ALARM LED indicator is located on the front panel.
Default settings for the DIP switch are set to OFF positions.
PWR
RPS
ON
OFF
DIP Position
ON
OFF
ON
OFF
11
PWR
RPS
Description
Primary power alarm
reporting is enabled.
Primary power alarm
reporting is disabled.
Redundant power alarm
reporting is enabled.
Redundant power alarm
reporting is disabled.