NOTE:
• Make sure the filter is securely locked. Otherwise, it would loosen and cause
dangerous.
• When activated carbon filter attached, the suction power will be lowered.
BULB REPLACEMENT
Important :
Change the LED light
1. Switch off the appliance and unplug it.
2. Unscrew the 4 screws on the outer glass frame panel by screwdriver
3. Pull out the light wire, and take down the outer glass frame panel
4. Unscrew the screws on the light bracket and replace the light
5. Connect the light wire and assemble the outer glass frame panel by screw.
Note:Pls make sure power off and take out the cooker hood from wall for
changing.Light replacement should carried out by qualified service personnel only.
•
ILCOS D code for this lamp is: DSL-5-S-450
– Max wattage: 5 W
– Voltage range: DC 12V
ENVIRONMENTAL PROTECTION:
This product is marked with the symbol on the selective sorting of
waste electronic equipment. This means that this product must not
be disposed of with household waste but must be supported by a
system of selective collection in accordance with Directive
2012/19/EU. It will then be recycled or dismantled to minimize
impacts on the environment, electrical and electronic products are
potentially dangerous for the environment and human health due to
the presence of hazardous substances.For more information, please
contact your local or regional authorities.
NOTE:
The following shows how to reduce total environmental impact (e.g. energy use) of the
cooking process).
(1) Install the cooker hood in a proper place where there is efficient ventilation.
(2) Clean the cooker hood regularly so as not to block the airway.
(3) Remember to switch off the cooker hood light after cooking.
(4) Remember to switch off the cooker hood after cooking.
The bulb must be r eplaced b y t he manufacturer, i ts
service agent or similarly qualified persons.
Always switch of f the el ectricity s upply before
carrying out any operations on the appliance. When
handling bulb, make sure it is completely cool down
before any direct contact to hands.
When handling globes hold with a cloth or gloves to
ensure perspiration does not come in contact with
the globe as this can reduce the life of the globe.
11