Safety Instructions - Frico ELV3333 Manual Del Usuario

Ocultar thumbs Ver también para ELV3333:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 25
GB
Maintenance
Note! Opening the heater cover should only be
done by a qualified installer.
Always disconnect the power supply before
opening the cover or doing any maintenance
work.
The appliance should be cleaned regularly both
inside and outside, to prevent overheating and
risk of fire but also to guarantee long life of the
heater.
Note! To keep the protection class it is very
important to tighten the screws properly when
the lid is put back again after installation or
maintenance.

Safety instructions

Incorrect installation and/or incorrect usage of the
fan heater can be hazardous.
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been
given supervision or instruction concerning use
of the appliance by a person responsible for their
safety.
Children should be supervised to ensure that they
do not play with the appliance.
Warning!
• Always disconnect the fan heater before opening
the cover or doing any electrical work.
• Incorrect installation can lead to personal
injury.
• Opening the heater by opening the cover etc
should only be done by a qualified installer
• This fan heater must not be used next to a
shower, bath or swimming pool.
• Place the fan heater away from flammable
materials
• Ensure that the area around the intake and
Type
Description
ELSRT
Control panel with room thermostat
ELSRT4
Control panel with room thermostat (control of 4 units) 255x360x110
KRT1900
External thermostat, IP55
10
Elektra V
exhaust grille is kept free from material which
could obstruct the air flow through the unit!
• During operation the surfaces of the unit are
hot!
• The unit must not be covered fully or partially
with clothes, or similar materials, as overheating
can result in a fire risk!
• The fan heater is fitted with a cable that, in the
event of damage, must be changed by a qualified
installer.
Important!
When using the heater as a portable, the brackets
must be turned in order to use them as a floor
stand (see fig 4 on page 3).
The guarantee is only valid if the units are used in
the manner intended by the manufacturer and in
accordance with the installation and maintenance
instructions.
Accessories
For fixed installation the heater can be controlled
by an external control panel with a built in
thermostat +5 – +35°C. It is also possible to use
only an external thermostat to control the heat
output. The ELSRT can only control one unit. For
parallel connection of up to 4 units the ELSRT4
can be used. When ELSRT is being used, the built-
in thermostat must be set to max and the output
selector on the unit to Off
See table below.
Dimensions
HxWxD
[mm]
175x150x100
165x60x57
.