3. Connection and Operation
Rear view
12VDC/24VAC
D
B
E
P
O
C
F G
B
PWR
C
Power input
D
LEVEL
P
PHASE
Phase setting
for vertical phase
E
LENS
F
1 ... 8
G
VIDEO OUT
HO,
Camera mount
HU
N
Dust cover
K,L
C/CS mount
M
Locking screw
O
D/N
All manuals and user guides at all-guides.com
Rear view
230VAC, with power cable
LED-indicator B lights green when the camera is switched on.
12VDC/24VAC or 230VAC power input. Power supply unit, see „Specifications".
First produce connections, then connect devices.
Output level adjustment with potentiometer D for DC controlled lenses.
(See lens mounting and settings).
Potentiometer regulator P for setting the phase for power synchronisation.
Adjustment to the same phase position when using several cameras, avoids
disruptive monitor re-synchronisation when using video switches (only possible
in models with AC supply voltage).
Connection E for DC- voltage or videosignal controlled lenses. Connect the cable
of lenses with automatic iris control to the supplied 4 pin DIN plug. (Only for
AI lenses which are designed for operation with 9-12VDC and 50mA max.)
DIP-Switch F to change the settings described under „DIP-Switch settings"
Video output G (BNC) for connection of external units (e.g. monitor, 75ohms)
1/4"-20UNC-thread HO/HU for camera mounting, for example on a tripod,
ceiling mount or P&T head.
To protect the CCD-sensors the camera module.
Always attach dust cover N when no lens is mounted.
CS mount L for CS mount lenses.
Insert the supplied C mount ring K if C mount lenses are used.
To adjust the backfocus open screw M, turn the at CS mount L until the focus
maximum is achieved and fasten the screw again.
Regulator O for manual setting of the switching point for day/night switching
18
Side view
K
N L
M
HO
HU