Orbegozo CA 08160/90 IN Manual De Instrucciones página 12

Campana extractora cassette
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CA 08160/90 IN
SUPPLIED PARTIES
Description
Picture
Cooker hood
Screws
(4 mm x 18 mm)
Valve
Reducer
INSTALLATION
If you have an air outlet to the outside, your hood can be connected as the figure below with a pull-out
tube.
1. Before installation, make sure the Hood is unplugged from the mains.
2. The hood should be placed at a distance of 65-75 cm on the kitchen surface for better performance.
3. Drill a hole in the base of the cabinet, 490*265mm for the model CA 08160 IN and 715*265 mm for the
model CA 08190 IN.
4. Remove the aluminum filter and remove the two front panel screws.
5. Use a screwdriver to secure the screws to the cabinet.
6. Replace the front panel with the two screws and replace the filter.
Quantity
1
8
2
1
12