Technical Data - Truma APC 310 Instrucciones De Uso Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 40
Charging process
The APC 310 has an electronic reverse battery protection.
The charging current is only released if the battery is cor-
rectly connected and there is a minimum voltage of 1.2 V.
The charging process is carried out in accordance with the
charging reference line with a minimum of performance loss
(see "Charging reference line"). When a temperature sensor
is used, charging is carried out on a temperature-dependent
basis.
Charging reference line
HL = Main charging phase
NL = Afterloading phase
EL = Trickle charging
U[V]
I[%]
I
100
U
1
U
2
50
U
0
0
HL
Charging voltage (at 20 °C)
Battery
HL – U
1
type
Liquid
14,4 V
Gel
14,4 V
AGM
14,5 V
Commissioning
The device is operational as soon as it is connected to the
APS 400-K and the battery.
Removing the clamping space cover
Unlock the clamping space cover by pressing the two straps
at the same time and then remove (see page 2, fig. A).
To attach the cover, push both straps into the slits of the hous-
ing shell and ensure that they click into place.
Maintenance
The power supply must always be completely discon-
nected before performing any maintenance work on the
device.
Clean the device and the ventilation slits with a dry and fluff-
free cloth.
Disposal
The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.
12
NL
E L
t[h]
NL
NL t[h]
EL – U
14,4 V
4
13,8 V
14,4 V
10
13,8 V
14,5 V
10
13,9 V

Technical data

Power supply
12 V
via APS 400-K
max. 22 V
via solar
(System voltage: 12 V,
idle voltage: panel max. 22 V,
current: max. 10 A,
corresponds to approx. 180 Wp)
Output
Charging voltage (± 0.05 V) – see "Charging reference line"
Arithmetic mean value, electronically controlled according to
the charging reference line IU
tection, open-circuit protected
Nominal current
10 A ± 0.5 A at 35 °C, above this, automatic power reduction
Residual ripple
< 5 %
Minimum battery voltage
1.2 V
Charging process
Automatic
Temperature-dependent control (optional)
The values of the automatic switching device refer to a battery
temperature of 20 °C. If a temperature sensor is used with the
battery, these values will vary in accordance with the battery
temperature.
High temperature
–> reduction of the threshold values.
Lower temperature –> higher threshold values.
Charging current lifter
max. 10 A
2
Voltage lifter
14.5 V
Monitoring under-voltage
OFF at 10.8 V
ON
at 12.5 V
Use
To charge the batteries with 12 V rated voltage and a capacity
of 50 – 150 Ah.
Storage temperature
-20 – +80 °C
Housing temperature (in operation)
max. +80 °C
Air humidity
5 – 95 % without thawing
Noise
< 10 dBA (at a distance of 1.5 m)
Dimensions (L x W x H)
360 x 150 x 103 mm
Weight
2.0 kg
The right to effect technical modifications is reserved!
U
, sustained short-circuit pro-
1
2

Publicidad

Tabla de contenido
loading

Tabla de contenido