If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
WARNING
!
To avoid possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
WARNING
!
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse box before wiring. All wiring must be in
accordance with National and Local codes and the ceiling
fan must be properly grounded as a precaution against
possible electrical shock.
5.1
Connect the green grounding lead from the hanger ball
and the green grounding lead from the hanger bracket to
the grounding conductor of supply (this may be a bare
wire or wire with green colored insulation). Securely
connect wires with wire connectors (supplied) (Figure 20).
5.2
Securely connect the fan white wire to the supply white
(neutral) wire using wire connector (supplied)
(Figure 21).
5. How to Wire Your Ceiling Fan
All manuals and user guides at all-guides.com
GROUND
CONDUCTOR SUPPLY
LISTED WIRE
CONNECTOR
GREEN WIRE
(GROUND) FROM
HANGER BALL
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
Figure 20
!
This product is designed to use only those parts supplied
with this product and/or any accessories designated
specifically for use with this product by Emerson Electric
Co. Substitution of parts or accessories not designated
for use with this product by Emerson Electric Co. could
result in personal injury or property damage.
Figure 21
13
WARNING
SUPPLY WHITE
(NEUTRAL)
LISTED WIRE
CONNECTOR
FAN WHITE WIRE
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF955L