Correcting the edge sensor position
Print out the edge sensor adjustment pattern, and correct the edge sensor position.
After printing, measure the distance and specify the parameter.
1
Hold down the
[ADJUST] menu appears.
á P R I N T E R
ß A D J U S T
2
Press the
key to enter the [ADJUST] menu.
# T E S T P R I N T S
> N O Z Z L E P R I N T
3
Press the
key.
4
Hold down the
SENSOR] menu appears.
# T E S T P R I N T S
> C H E C K E D G E S E N S O R
5
Press the
key.
# T E S T P R I N T S
* O K ?
6
Press the
key.
# T E S T P R I N T S
* E X E C U T I N G
7
Judge the printing results.
Measure the margin of the printing result with a square,
and obtain a difference between the measured margin
and the value (15mm) shown in the specifications.
If the difference is 15mm, complate this procedure.
If not, follow the prcedure below to correct the value.
508 nozzles
(Blank by the
even number
15mm
508 nozzles
(All nozzles)
key until the
M E N U
S E T U P â
H E A T E R à
key until the [CHECK EDGE
of heads)
8
Press the
key to enter the [ADJUST] menu.
# E D G E S E N S O R A D J V A L
> ± Y . Y m m
9
Press the
key to display the [EDGE SENSOR
ADJ VAL] menu, and press the
10
Based on the printed sensor adjustment
pattern, enter the correction value of the edge
sensor position.
# E D G E S E N S O R A D J V A L
> ± Y . Y m m
Y . Y
11
Press the
key to decide the entered value.
# E D G E S E N S O R A D J V A L
> + 0 . 0 m m
12
Press the
key to return to the higher-level
menu.
To obtain the correction value:
Obtain the correction value by measuring the margin
setting the reference value to 15 mm.
<Example>
The margin is 14 mm: The correction value is -1.0 mm.
The margin is 16 mm: The correction value is +1.0 mm.
key.