OPERATING INSTRUCTIONS

Preparing the Spray Area

1.
Clean gross filth by using standard manual cleaning protocols.
2. Close the room to the general public for cleaning. Place signs
or warning indicators on doors that indicate no one should
enter the room.
3. Power off any sensitive electrical devices. Devices do not need to
be unplugged.

Unit Operation/Setup

1.
Choose the appropriate Clorox-approved product for cleaning,
sanitizing or disinfecting.
2. Put on appropriate PPE. See section on PPE on page 5.
3. Mount desired Clorox-approved product on Clorox® Total
360® Electrostatic Sprayer base. Ensure that the bottles are
positioned with the opening facing up and the opening facing
the dispensing tubes.
4. Unscrew the lid on the Clorox-approved product of your choice,
remove seal (if present), and connect the Clorox® Total 360®
Electrostatic Sprayer dispensing cap to the bottle. Be sure the
cap is screwed all the way down; do not overtighten.
5. Unwrap electrical cord completely and plug Clorox® Total
360® Electrostatic Sprayer into a grounded, three-pronged
outlet. See EXTENSION CORD section for extension cord
specifications.
NOTE: For outside or wet environment application, use a
GFCI (ground fault circuit interrupter) inline adapter or outlet
to help avoid risk of electrical shock. The GFCI should be
placed as close to the outlet as possible.
6. Locate the On/Off switch on the base unit. Push the Total
360® sprayer to the "ON" position. A light will illuminate on the
sprayer instrument panel.
7.
Remove the sprayer from the unit.
8. The system is now ready for use.
9. Priming the Clorox® Total 360® Electrostatic Sprayer: Depress
into an inconspicuous corner, container or drain. Spray the
Clorox® Total 360® Electrostatic Sprayer for up to 20 seconds to
generate a steady flow of solution.
10. When spraying, a second indicator light will illuminate on the
sprayer instrument panel when the sprayer button is depressed.
NOTE: Sprayer will automatically stay on until sprayer button
is depressed an additional time.
NOTE: Unit will not operate properly below 40°F (4.5°C).
If the unit has been stored where temperatures are below
40°F (4.5°C), move the unit to a warm environment and allow
the unit to acclimate before operation.
Sprayer Operation
1.
Position Clorox® Total 360® Electrostatic Sprayer in a rear
corner of the area.
2. Direct the spray wand at the desired surface.
3. Begin to spray. Press the sprayer button once to initiate
spraying. Press once to stop flow of the sprayer.
4. Follow a continuous path around the area, working from high
to low areas, moving the sprayer in a sweeping motion until
surfaces are thoroughly wet. Optimal spray distance away from
surface is 3–4 feet (0.9–1.2 meters).
5. After spraying, keep the area closed to the public until
applicable bystander re-entry times are reached (see the
product SDS for information on bystander re-entry times).
If no re-entry time is indicated, keep the area closed until
product contact times are reached or surfaces are visibly dry.
6. Remove the closed sign from the door.
8 |
EN

Changing Clorox-Approved Products

1.
Stop spraying the Clorox® Total 360® Electrostatic Sprayer.
2. Disconnect the bottle connection from the Clorox-approved
product that is to be changed and remove from the sprayer.
Cap the removed product if it is being stored.
3. Purging the Clorox® Total 360® Electrostatic Sprayer: Depress
into an inconspicuous corner, container or drain. Spray the
Clorox® Total 360® Electrostatic Sprayer for about 20 seconds
to purge the system.
4. Choose the appropriate Clorox-approved product for cleaning,
sanitizing or disinfecting.
5. Mount desired Clorox-approved product on Clorox® Total
360® Electrostatic Sprayer base. Ensure that the bottles are
positioned with the opening facing up and the opening facing
the dispensing tubes.
6. Unscrew the lid on the Clorox-approved product of your choice,
remove seal (if present), and connect the Clorox® Total 360®
Electrostatic Sprayer dispensing cap to the bottle. Be sure the
cap is screwed all the way down; do not overtighten.
7.
Priming the Clorox® Total 360® Electrostatic Sprayer: Depress
into an inconspicuous corner, container or drain. Spray the
Clorox® Total 360® Electrostatic Sprayer for about 20 seconds
to generate a steady flow of solution.

After Use and Storage

1.
Stop spraying the Clorox® Total 360® Electrostatic Sprayer.
2. Disconnect the bottle connection from the Clorox-approved
product that is to be changed and remove from the sprayer.
Cap the removed product if it is being stored.
3. Emptying drip cup holder (if necessary): Unscrew drip cup,
making sure to hold it level to prevent spillage. Remove and
empty the drip cup. Reinstall the empty drip cup by rotating it
in the opposite direction until it is snug.
4. Purging the Clorox® Total 360® Electrostatic Sprayer:
Depress into an inconspicuous corner, container or drain.
Spray the Clorox® Total 360® Electrostatic Sprayer until no liquid
comes out of the nozzle.
5. Turn off the unit. Indicator lights on the sprayer instrument
panel should no longer be illuminated and power button should
be in the OFF position.
6. Unplug the Clorox® Total 360® Electrostatic Sprayer from wall.
7.
Wrap cord on cord holder on the Clorox® Total 360® base unit.
8. Store in a safe, dry place.