Maintenance; Exterior Frame; Peristaltic Pump; Specifications - CLOROX Pro Total 360 Manual Del Operador

Atomizador electrostático
Ocultar thumbs Ver también para Pro Total 360:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE

In order for the Clorox® Total 360® Electrostatic Sprayer to remain
functional, the equipment should be cleaned on a regular basis.
In addition to general cleaning of the unit, one user-serviceable
area — the peristaltic pump — may need to be serviced.
NOTE: As the sprayer becomes dirty from typical use, a 70%
isopropyl alcohol cleaner that is manually applied is recommended
on outside surfaces.
The sprayer body has no serviceable parts inside. DO NOT OPEN
THE UNIT SHELL, AS DOING SO WILL VOID THE WARRANTY ON
THE SPRAYER. If you need to have your sprayer serviced, contact
Clorox® Total 360® Technical Support at CloroxTotal360Support.com.

Exterior Frame

To clean the exterior of the Clorox® Total 360® Electrostatic Sprayer
1.
Purge all chemistry from the device.
2. When not in use, ensure the device is powered off and unplug
the power cord from the wall outlet and device.
3. Wipe exterior surfaces of the device, including hose and nozzle,
with a slightly damp cloth or towel to remove visible soil.
Be sure that the cloth is well wrung out, and excess moisture
has been removed.
4. For additional soil removal, wipe the exterior surfaces with
a microfiber cloth that has been soaked in warm, soapy water.
Be sure that the cloth is well wrung out, and excess moisture
has been removed.
5. Let device dry thoroughly before operation is resumed.

Peristaltic Pump

Tube Nuts
1.
Disconnect the clear tubing inlet and outlet by twisting the
Tube Nuts counterclockwise until both tubes have separated.
2. Rotate the Cover counterclockwise and pull the pump assembly
free from the unit.
3. Install the new Pump Assembly in the reverse order that it was
disassembled.
Tube Leader Assembly
Carriage Assembly
Cover
SPECIFICATIONS for 115V model
Volts
~115V
Running AMPS
6.0
Temperature
Minimum Operating Temperature 40°F
(4.5°C). Allow to acclimate to room
temperature if stored below 40°F (4.5°C).
Frequency
60 Hz
Standard Hose Length
7 ft. (2.13 m)
Dimensions
25 3/8 in. (64 cm) H x 10 1/16 in.
(26 cm) W x 17 1/8 in. (43 cm) L
Air Line Pressure
35 psi (2.4 Bar)
Weight – Empty
43 lbs (20 kg)
Weight – Full
59 lbs (27 kg)
Shipping Weight
52 lbs (24 kg)
Flow Rate
110–130 mL/min
SPECIFICATIONS for 240V model
Volts
~240V
Running AMPS
3.0
Frequency
50 Hz
Temperature
Minimum Operating Temperature 40°F
(4.5°C). Allow to acclimate to room
temperature if stored below 40°F (4.5°C).
Standard Hose Length
7 ft. (2.13m)
Dimensions
25 3/8 in. (64 cm) H x 10 1/16 in.
(26 cm) W x 17 1/8 in. (43 cm) L
Air Line Pressure
35 psi (2.4 Bar)
Weight – Empty
43 lbs (20 kg)
Weight – Full
59 lbs (27 kg)
Shipping Weight
52 lbs (24 kg)
Flow Rate
110–130 mL/min
EN
| 9

Publicidad

Tabla de contenido

Solución de problemas

loading

Productos relacionados para CLOROX Pro Total 360

Este manual también es adecuado para:

Clx1100

Tabla de contenido