12
TECHNICAL DATA
Ambient temperature,
operation
1)
Object with 90% remission (based on standard white DIN 5033)
2)
16 VDC to 30 VDC, without load
3)
10 VDC to 16 VDC, without load
4)
Signal transit time with resistive load in switching mode. Deviating values possible in COM2 mode.
5)
With a light/dark ratio of 1:1 in switching mode. Deviating values possible in IO-Link mode.
6)
Pursuant to EN 60529
7)
Replaces IP69 K pursuant to ISO 20653: 2013-03
8)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
9)
Do not bend cables below 0°C.
12.1
Dimensional drawings
en
13
Annex
13.1
Conformities and certificates
34
O P E R A T I N G I N S T R U C T I O N S | WTB26
WTB26P-xxxxx1,
WTB26Pxxxxx4
WTB26P-xxxxx5
–40 °C ... +60 °C
–40 °C ... +60 °C
9)
24.6
(0.97)
Ø 5.2
(0.2)
4
2
1
3
10
(0.39)
12.9
(0.51)
6.4
(0.25)
Figure 23: Dimensional drawing 1, cable
Preferred direction of the target
1
object
Center of optical axis, sender
2
Center of optical axis, receiver
3
Fixing hole Ø 5.2 mm
4
connection
5
Display and setting elements
6
You can obtain declarations of conformity, certificates, and the current operating
instructions for the product at www.sick.com. To do so, enter the product part number
in the search field (part number: see the entry in the "P/N" or "Ident. no." field on the
type label).
WTB26I-xxxxx1
–40 °C ... +60 °C
9)
48.1
(1.89)
6
1
40
3
(1.57)
44.2
(1.74)
4
7.1
(0.28)
10.8
5
(0.43)
25
(0.98)
8.1
(0.32)
38.8
(1.53)
53.3
(2.1)
Figure 24: Dimensional drawing 2, male
connector
WTB26I-xxxxx4
–40 °C ... +60 °C
9)
48.1
(1.89)
24.6
(0.97)
Ø 5.2
(0.2)
6
4
2
63.9
(2.52)
40
(1.57)
19.7
(0.78)
44.2
(1.74)
4
5
25
(0.98)
M12
6.3
(0.25)
39
(1.54)
53.3
(2.1)
8020354.1DS8/2021-11-24 | SICK
Subject to change without notice
9)
7.1
(0.28)
10.8
(0.43)
8.1
(0.32)