Deactivating Panic Mode
In the event the user does not want to access a panic button through the remote control, it can be deactivated from the Code
Encryptor 3's memory.
1. Unplug the wire harness from the Code Encryptor 3.
2. Press and HOLD the program button.
3. While HOLDING the program button, plug the CE 3 harness back in. The LED located on the front will turn ON.
4. Wait until the LED turns "OFF".
5. Once the LED has turned "OFF" release the button. Auto recognition will start.
TEST THE REMOTES
Press and Release button 1 to Arm "Away"
Press and Release button 2 to "Disarm"
Press and Hold button 1 for 3 seconds to Arm "Stay" or "Bypass"
Press and Hold buttons 1 and 2 for two seconds to activate "Panic"
NOTE: The Code Encryptor 3 will arm in the AWAY mode even if you
are outside the house. We do however recommend that you Arm the
alarm system within sight of the status LED or keypad to verify that
the system has received and responded to your remote request.
SOLUCIÓN DE PROBLEMAS
PROBLEM
Presiono el Botón 1 pero no pasa nada.
Mantengo presionados los botones 1 y 2
y no me entra el pánico.
Estoy usando un DSC 1832 o
cualquier PowerSeries y la alarma no
se ARMARÁ con el control remoto.
Estoy usando un DSC Power Series y la alarma no
se DESARMARÁ con el control remoto.
Estoy usando un panel GE Caddx NX y
solo ARMARÁ en el modo INTERIOR.
La unidad no parece identificar el
panel que estoy usando.
ESSPECIFICACIONES
513-1224
Receptor:
• 12VDC Power Input
• Channels 1 & 2 Data outputs
• Channel 3 Relay (N/O, Common) 10amp - momentary
• Channel 4 selectable: Form C Relay (N/O, N/C, Common) 5amp - momentary
• Channel 5 (top 2-buttons at same time) - Keypad panic data output (Programmable On or OFF)
Frequency: 433 MHz
Stand by Power Consumption: 13mA on standby (40mA max)
Temperature Range: -5°F to 160°F (Indoor use only)
Remote Control Battery: 6VDC Mini (2x Part #CR-2032) Replace battery once a year.
Ê800-04965iŠ
800-04965 8/09 Rev. A
¿Programó un código de usuario de cuatro dígitos válido en Code Encryptor 3?NOTA:
El código que programe en Code Encryptor 3 debe ser un código maestro o uno de los
códigos de usuario actuales.
Press button 3. If you do NOT hear a"click"at the receiver, see To Add a New Remote
inthe Adding/Deleting Remotes section and learn that remote into the Code Encryptor 3.
¿Programó el panel para el pánico del teclado?
Programe el Code Encryptor 3 para pánico. Encienda pánico (consulte la sección Modo de pánico)
Asegúrese de programar el panel de alarma para "Habilitación de tecla rápida", sección de
programación 015, la luz n. ° 4 está ENCENDIDA. Apague el panel de alarma y vuelva a
encenderlo. Espere al menos 60 segundos antes de intentar usar el control remoto.
Ingrese a la programación del panel. Vaya a la sección de programación 017.
Asegúrese de que la luz # 1 esté encendida.
Apague el panel, espere al menos 60 segundos y vuelva a encender el panel.
Vuelva a programar el código de usuario en el receptor CE3.
Call Technical Support at 800-645-7492.
Technical Support: M-F 8AM-5PM EST (800) 645-7492; Sales: (858)
PANIC
HOLD
BOTH
ARMED
GARAGE
DOOR
OPEN/CLOSE
SOLUTION
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2009 Honeywell International Inc.
DISARMED
PROGRAMMED
RELAY
OUTPUT
CE3-002-V0
www.honeywell.com/security
https://www.facebook.com/groups/591852618012
ventas@rosarioseguridad.com.ar
rosarioseguridadok
+54 9 341 6708000
Rosario Seguridad
+54 9 341 6591429
Avenida Presidente Perón 3998 - Rosario - Santa Fe - Argentina

Publicidad

loading

Este manual también es adecuado para:

Code encryptor 3