Descargar Imprimir esta página

When You Think That Trouble Has Occurred - Mitsubishi Electric MS-A09WA Manual De Instrucciones

Ocultar thumbs Ver también para MS-A09WA:

Publicidad

Idiomas disponibles

Idiomas disponibles

• OPERATING INSTRUCTIONS •
W
HEN YOU THINK THAT TROUBLE HAS OCCURRED
Even if these items are checked, when the unit does not recover from
the trouble, stop using the air conditioner and consult your dealer.
Symptom
Indoor Unit
The unit cannot be operated.
The horizontal vane does not
move.
The unit cannot be operated
for about 3 minutes when
restarted.
The fan stops during the DRY
operation.
Mist is discharged from the air
outlet of the indoor unit.
The swing operation of the
HORIZONTAL VANE is
suspended for a while, then
restarted.
The air fl ow direction changes
during operation.
The direction of the horizontal
vane cannot be adjusted with
the remote controller.
The unit starts operation by
itself when the main power
is turned on, though it isn't
operated with the remote
controller.
Outdoor Unit
Water leaks from the outdoor
unit.
The fan of the outdoor unit
does not rotate even though
the compressor is running.
Even if the fan starts to rotate,
it stops soon.
En-9
SG79Y951H01_EN.indd 9
All manuals and user guides at all-guides.com
Explanation & Check points
• Is the breaker turned on?
• Is the power supply plug connected?
• Is the ON timer set?
Page 7
• Is the horizontal vane installed correctly?
• Is the fan guard deformed?
• This protects the unit according to instruc-
tions from the microprocessor. Please
wait.
• In DRY operation, the unit operates using the
same refrigerant circuit as in COOL opera-
tion. DRY operation time has to be reduced
in order to lower humidity without much room
temperature decreasing. So the compres-
sor sometimes stops, and at the same time
the indoor fan stops. This prevents water
condensed on the heat exchanger from
evaporating again.
• The cool air from the unit rapidly cools mois-
ture in the air inside the room, and it turns
into mist.
• This is for the swing operation of the HORI-
ZONTAL VANE to be performed normally.
• When the unit is operated in COOL or DRY
mode, if the operation continues with air
blowing down for around 1 hour, the direction
of the air fl ow is automatically set to position
(1) to prevent water from condensing and
dripping.
• These models are equipped with an auto re-
start function. When the main power is turned
off without stopping the unit with the remote
controller and is turned on again, the unit
starts operation automatically in the same
mode as the one set with the remote control-
ler just before the shut off of the main power.
Refer to "Auto restart function"
page 5
• During COOL and DRY operations, pipe or
pipe connecting sections are cooled and this
causes water to condense.
• When the outside temperature is low dur-
ing cooling operation, the fan operates
intermittently to maintain sufficient cooling
capacity.
Symptom
Remote controller
The display on the remote
controller does not appear
or it is dim. The indoor unit
does not respond to the
remote control signal.
Does not cool
The room cannot be cooled
suffi ciently.
Airfl ow
The air from the indoor unit
smells strange.
Sound
Cracking sound is heard.
The sound as burbling is
heard.
Mechanical sound is heard
.
from the indoor unit.
The sound of water fl owing
is heard.
In the following cases, stop using the air conditioner and consult
your dealer.
• When water leaks or drips from the indoor unit.
• When the upper operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/OFF
type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An ampli-
fi er may be required for the affected device.
• When an abnormal sound is heard.
Explanation & Check points
• Are the batteries exhausted?
Page 4
• Is the polarity (+, -) of the batteries correct?
Page 4
• Are any buttons on the remote controller of
other electric appliances being pressed?
• Is the temperature setting appropriate?
Page 5
• Is the fan setting appropriate? Please
change fan speed to higher setting.
Page 6
• Are the fi lters clean?
Page 8
• Is the fan or heat exchanger of the indoor unit
clean?
• Are there any obstacles blocking the air inlet
or outlet of the indoor or outdoor unit?
• Is a window or door open?
• When a ventilation fan or a gas cooker is
used in a room, the cooling load increases,
resulting in an insuffi cient cooling effect.
• When the outside temperature is high, the
cooling effect may not be suffi cient.
• Are the fi lters clean?
Page 8
• Is the fan or heat exchanger of the indoor unit
clean?
• The unit may suck in an odor adhering to the
wall, carpet, furniture, cloth, etc. and blow it
out with the air.
• This sound is generated by the expansion/
contraction of the front panel, etc. due to
change in temperature.
• This sound is heard when the outside air is
absorbed from the drain hose by turning on
the range hood or the ventilation fan, making
water fl owing in the drain hose to spout out.
This sound is also heard when the outside air
blows into the drain hose in case the outside
wind is strong.
• This is the switching sound in turning on/off
the fan or the compressor.
• This is the sound of refrigerant or condensed
water fl owing in the unit.
4/9/07 4:20:51 PM

Publicidad

loading

Este manual también es adecuado para:

Ms-a12waMsy-a15naMsy-a17na