4.2 SWITCHING ON THE SELECTOR
Once connected, the Digital Selector will turn on and display the status of the automatic door.
DESCRIPTION
The blue bidirectional status LED flashes
The blue door status LED turns on
4.3 DOOR CONTROL UNIT RESET
DESCRIPTION
Press and hold the selector key for at least 10 seconds until the door
status LEDs start to turn on in clockwise order.
At the end of the operation, the selector will go back to indicate the active
status of the door by illuminating the corresponding LED.
NOTES: the first manoeuvre after resetting the card will be performed slowly. The reset cycle lasts
approximately 10 seconds.
4.4 CHANGING THE STATUS OF THE DOOR
DESCRIPTION
Press and hold the selector key for at least 2 seconds
The door active status LED will start flashing
Press the button several times until the desired status is selected
After 2 seconds from the selection, the LED will become fixed and the
door will acquire the chosen status.
NOTES: If a Lock Delay greater than zero has been programmed and the lock status is selected, the internal
radar LED will light up and the lock status LED will flash; when the time has elapsed, the lock status LED will
become fixed and the automatic door will be locked.
4.5 ERROR MESSAGES
DESCRIPTION
In case of a communication error between the selector and the control
unit, the error LED will flash quickly
In the event of an error related to the RXLEV control unit, the error LED
will flash slowly
In the event of a cyclical test in progress, the error LED will remain on
In case of low battery, the battery LED will flash slowly
EXAMPLE
BLUE
EXAMPLE
> 10s
BLUE
EXAMPLE
>2s
BLUE
+
+
BLUE
EXAMPLE
0,5s +
0,5s
2s +
2s
2s +
2s