Further Details - Advanced Menu; Advanced Menu Structure; Board Parameters Menu - Key Automation EASY2 Instrucciones Y Advertencias Para Su Instalación Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN

4 - FURTHER DETAILS - ADVANCED MENU

4.1 - Advanced Menu Structure

BIDIRECTIONAL
OPEN
BIDIRECTIONAL
OPENING
EXIT
LOCKED
PHARMACY
INTERNAL RADAR
LOCKED
PHARMACY

4.2 - Board parameters menu

When the "Board Parameters" menu is accessed, the screen shows
the word "loading...". Immediately after this message, the user can
Function
Default
1.
70
2.
40
3.
8
4.
3
5.
2
6.
4
7.
70
8.
38
9.
16
A.
2
B.
75
C.
0
D.
0
E.
0
F.
0
G.
0
H.
1
14
PARTIAL
MANUAL
ENTRY
PARTIAL
FREE
EXTERNAL RADAR
EXIT
DELAYED BLOCK
ERROR
Min
Max
Value
5
80
Opening speed (cm/sec)
5
50
Closure speed (cm/sec)
1
15
Opening deceleration speed (cm/sec)
1
15
Closure deceleration speed (cm/sec)
0
16
Deceleration in opening
0
16
Deceleration in closing
10
300
Approach space at opening
10
300
Approach space at closing
1
100
Force on obstacle
1
60
Pause time (sec)
Percentage of partial opening run (50 to
50
99
99%)
0
1
Type of electric lock
0
1
Traffic adaptation
0
2
If door is forced
0
4
If there is power outage
0
4
If battery is dead
0
1
Direction of motion
PASSWORD requested
0 * * *
Ok
E x it
display and/or modify every single parameter. ATTENTION: The
values can be different depending on the weight class of the door.
BOARD
PARAMETERS
-
+
BOARD
DISPLAYS
-
+
ERROR
DISPLAYS
-
+
BOARD
ACTIONS
-
+
SELECTOR
STATUS
-
+
UTILITY
0 = monostable
1 = bistable
0 = not present
1 = present
0 = resistance to force
1 = opens
2 = stays open
0 = functioning continues
1=opens even if locked
2=closes and locks
3=opens only if unlocked
4=closes but does not lock
0 = functioning continues
1=opens even if locked
2=closes and locks
3=opens only if unlocked
4=closes but does not lock
0=right hand opening
1=left hand opening
Ok
4.2
Ok
4.3
Ok
4.4
Ok
4.5
Ok
4.6
Ok
4.7

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido