It is recommended that the heater is located near the highest point of use hot water to prevent loss of
heat by the pipes. Locate the water heater with easy a fast access to valves and control panel.
Water Heater corrosion and deterioration of the components can be caused by the heating of
airborne chemical vapors. Examples of typical compounds potentially corrosive are: spray
propellants, cleaning solvents, refrigerants, pool chemicals, calcium or sodium chloride, waxes and
chemical processes. These materials are corrosive at very low concentration levels with little or no
odor to detect their presence.
NOTE: DAMAGE CAUSED BY EXPOSURE OR CORROSIVE VAPORS IS NOT COVERED BY THE
WARRANTY. DO NOT USE THE WATER HEATER IF EXPOSURE OCCURS. DO NOT STORE
ANY POTENTIALLY CORROSIVE COMPOUNDS IN THE SURROUNDING WATER HEATER.
This water heater must be located in an area where the safety valve of the tank, water line
connections and the drain valve in the event of a spill will not cause harm to the area near to the
heater or the floors of the structure.
If you open the heater for the purpose of cleaning or a similar service or changes of any thermostat,
make sure the heater is disconnected before performing any work.
DANGER
The water temperature at 55°C (125°F) can cause severe
burns and damage to exposed skin.
Children, disable and the elderly require care for the use of hot
water.
The pressure relief valve is required see manual.
3