Connect To The Electronic Control Lock
You can connect different electronic control lock to the outdoor doorbell, first you need to buy a power
supply controller for the lock, a electronic control lock. You can connect an electronic lock, or an electric
mortise lock, or a magnetic lock, or a cathode lock. Please refer to the following diagram to connect the
monitor, the outdoor doorbell, the power supply for the door lock and the electronic control lock.
L+: The positive of the lock, L-: the Negative of the lock.
The power supply controller is power for the electronic control lock.
For an electronic lock, please connect L+ port to NO port of the power supply controller, connect L- port
to COM port of the power supply controller, connect GND port to GND port of the power supply controller,
connect 12V port to 12V port of the power supply controller.
For an electric mortise lock, or a magnetic lock, or a cathode lock, please connect L+ port to NC port the
power supply controller, connect L- port to COM port of the power supply controller.
For all the locks, please connect GND port and PUSH port of the power supply controller to the 2 pin cable
connected to the unlock ports of the outdoor doorbell.
Also you can install a push switch for the lock, please connect positive line of the switch to PUSH port of
the power supply controller, connect negative line to GND port of the power supply controller.
GB-11
Affixation
screw
Waterproof cover
Screw anchors
Note on door lock connection
The electric locks are usually divided into NC lock and NO lock, their wiring is different,
the NC lock need to work with the additional power supply control.
Note:
1. The doorbell or the monitor will not provide the power to door lock.
2. The doorbell can support door locks within 30V.
3. Door lock's power supply depends on its door lock, if the door lock is 12V,
the corresponding power supply is 12V, etc.
4. Make sure the input voltage from the monitor to the outdoor doorbell must reach 11.7V when unlocking.
NO Lock: Always closed when power or power off, only open when press unlock.
NC Lock: Always open when power off. Closed when power and open after press unlock.
NO lock
Electronic lock
NC lock
Electric mortise lock
1 2 3
4 5 6
7 8 9
0 #
*
Magnetic lock
Access controller
Cathode lock
Note:
Since this manual is a multilingual version, some specific operations are omitted.
If you have any questions, please send an email to:
Power supply control
Doorbell
DOOR
EXIT
Monitor
1
EXIT
2
4 pin cable
support@tmezon.com
GB-12
Monitoring
Talk
Unlock
Hang up