MAINTENANCE
CLEANING THE BOILER
To maintain your steam generator in good condition and to ensure constant performance, we recommend
that you periodically clean the boiler
CLEANING INSTRUCTIONS
1.
Before cleaning the boiler, please make sure that the boiler is at room temperature, that it
has not been used for at least 12 hours, and that the steam generator iron is disconnected
from the power source.
2.
Unscrew and remove the boiler cap (6). Turn the steam generator iron over and empty
all the remaining water from the boiler.
3.
Dissolve one package of the provided descaling solution in 0.65L (22 oz) of water or mix
equal parts of water and white vinegar, for a maximum of 0.65L (22 oz). Pour it into
the boiler using the provided funnel and leave the boiler cap open. Let sit overnight.
4.
Drain the boiler and rinse thoroughly with clean water.
5.
Refer to page 7 for instructions on how to refill and turn on the machine.
ATTENTION:
It is not recommended that you use any other chemical to clean this product.
Doing so will automatically void the warranty.
All manuals and user guides at all-guides.com
after every 50 hours of use or less depending on the water hardness.
en
10