M 540211102211072018
GENERAL WARNING
•
This hood has been developed and produced in accordance with
DS/EN 60335-1.
•
This hood is only suitable for use in private households; any
other use will invalidate the warranty.
•
All installations must be carried out by a qualified technician in
accordance with the instructions set out by Thermex Scandina-
via A/S (Thermex) and the Laws in force.
•
Thermex disclaims any liability for damage resulting from im-
proper installation, assembly, operation or incorrect settings.
BEFORE INSTALLATION/OPERATION
•
check the hood for transport damage, defects and missing
parts immediately upon receipt.
•
Transport damage should be reported immediately to the
transport company and Thermex upon receipt.
•
Any defects and/or missing parts should be reported to Ther-
mex within 8 days of receipt and prior to installation/operation.
INSTALLATION
•
The hood is designed to operate at 230 volts ± 10% ~ 50 Hz in
accordance with EN 50160
•
connect the hood with the attached plug. NOTE: If the plug has
an Earth terminal, the hood MUST be earthed.
•
For models with an external motor it is important NOT to use
common zero when installing the hood and motor, as this will
affect operation.
•
when using an external motor from another supplier, the mo-
tor MUST be compatible with the selected hood. Failure to
comply with this will invalidate the warranty.
•
The hood must not be connected to the mains before installa-
tion is complete.
•
The air must not be discharged from the hood into a pipe used
for extraction from devices using gas or other combustible ma-
terials. Such devices must have a separate vent.
•
The national legislation on air emissions must be observed.
•
Always use the original exhaust measurements. Reduction of
the exhaust size will reduce performance and increase sound
levels.
•
The exhaust from the hood to the outside should be as short as
possible in order to maximise the efficiency of the hood.
•
The number of bends on the exhaust should be minimal in or-
der to maximise the efficiency of the hood.
•
Thermex recommends that vent hoses insulated against no-
ise and condensation for all bushings in unheated rooms are
always used.
•
Thermex recommends using a silencer when flexible hoses are
used in order to minimise sound levels.
•
when using flexible hoses, always ensure that they have been
fully extended in order to minimise air resistance and thereby
maximise suction performance.
•
Different materials require different rawlplugs and screws.
Rawlplugs and screws suitable for the material onto which the
hood will be mounted on must be used.
•
If the instructions for the installation of screws and fittings are
not followed, it may result in electrical shock.
•
The minimum distance to gas hobs from the burner's edge to
the underside of the hood MUST be a minimum of 65 cm in
accordance with EN 60335-2-31.
•
For cupboard-integrated, suspended and wall-mounted hoods,
Thermex recommends that the distance between the hob and
cooker hood is between 50 cm and 70 cm in order to ensure
maximum suction.
•
Always check the minimum distance between the hob and the
cooker hood, as indicated in the instructions for the hob. The
instructions for the hob MUST be observed if a greater distance
than that recommended by Thermex is indicated in this ma-
nual.
•
Thermex recommends that the distance between the hob and
the hood should not exceed 3 meters for ceiling-integrated mo-
dels.
THERMEX VERTIcAL PE 1050