Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the
Helpline or your POLAR dealer.
Fault
The appliance is not
working
The appliance turns on,
but the temperature is
too high/low
The appliance is
unusually loud

Technical Specifications

Model
Voltage
Power
CS586
220-240V
165W
50Hz
CS586_ML_A5_v2_20200402.indb 7
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Too much ice on the evaporator
Condenser blocked with dust
Door not shut properly
Appliance is located near a
heat source or air flow to the
condenser is being interrupted
Ambient temperature is too high
Appliance is overloaded
Loose nut/screw
The appliance has not been
installed in a level or stable
position
Current
Range
1.0A
+2°C ~ +8°C
Solution
Check the unit is plugged in correctly and
switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Defrost the appliance
Call POLAR agent or qualified Technician
Check door is shut and seals are not
damaged
Move the refrigerator to a more suitable
location
Increase ventilation or move appliance to a
cooler position
Reduce the amount of food stored in the
appliance
Check and tighten all nuts and screws
Check installation position and change if
necessary
Capacity
Dimensions
Refrigerant
(Litres)
H x W x D mm
301
R600a 60g
1900 x 448 x 682
UK
Weight
(kg)
71
7