MAINTENANCE
Most components can be inspected by removing the hood. To inspect the head you must disassemble the component-carrying plate which can be hung
on hung on the burner body in two different positions to make work as practical as possible. The motor, transformer and solenoid valve are connected
via a connector while the photo-resistor is push-locked into place.
1) Undo the lid screw to gain access to the
interior of the burner.
3) The plate can be hung up in two different ways
(fig. C - D); it is recommended that you hang it
as illustrated in fig. D.
5) Unscrew the nozzle with wrench and counter - wrench.
Fig. A
13 / 14
0006080735_201104
2) Undo the 4 screws of the plate, as indicated,
in order to access nozzle, electrodes and pre-
heater (if fitted).
4) To disassemble the nozzle first remove the
electrodes disk unit by undoing the screw as
illustrated in the diagram.
Fig. B
E
N
G
L
I
S
H