English
OPTIONAL ACCESSORIES
Sequential Trip Mechanism Kit (Code No. 876762)
(Single Shot Parts)
Pneumatic Tool Lubricant
.8 oz. (25 cc) oil feeder
4 oz. (120 cc) oil feeder
1 quart (1 ltr) can
NOTE: Accessories are subject to change without any
obligation on the part of HITACHI.
APPLICATIONS
<NV83A2, NV65AC>
Construction wooden work such as floor and wall
framing, roof decking, subflooring.
Mobile and modular home construction.
Making wooden boxes, palletes, and drums.
Packing operations in manufacturing plants, and other
types of packing and crating work in general.
<NV50A1>
Making wooden boxes, and light pallets.
Making wooden furniture, wooden sash, and other
wooden products.
Packing operations in manufacturing plants, and other
types of packing and crating work in general.
Construction work in general such as prefabricated
houses.
NOTE:
Aluminium nails may bend when used on hard
surfaces.
Test before use.
BEFORE OPERATION
Read section titled "SAFETY" (pages 4 – 7).
Make sure of the followings before operation.
WORKING ENVIRONMENT
WARNING
No flammable gas, liquid or other flammable
objects at worksite.
Clear the area of children or unauthorized
personnel.
... sold separately
(Code No. 877153)
(Code No. 874042)
(Code No. 876212)
— 10 —
AIR SUPPLY
DANGER
WARNING
Never connect Nailer to pressure which
potentially exceeds 200 psi (13.7 bar 14 kgf/cm
Never use non relieving coupler on Nailer.
1. Power source
Use only clean, dry, regulated compressed air as a
power source for this Nailer.
Air compressors used to supply compressed air to this
Nailer must comply with the requirements of the latest
version of ANSI Standard B 19.3 "Safety Standard For
Compressors For Process Industries."
Moisture or oil in the air compressor may accelerate
wear and corrosion in the Nailer.
Drain daily.
2. Filter-Regulator-Lubricator
Use a regulator with a pressure range of 0 – 120 psi
(0 – 8.3 bar 0 – 8.5 kgf/cm
Filter-regulator-lubricator units supply an optimum
condition for the Nailer and extend the Nailer life.
These units should always be used.
Filter ............. The filter removes moisture and dirt
mixed in compressed air.
Drain daily unless fitted with an
automatic drain.
Keep the filter clean by regular
maintenance.
Regulator ..... The regulator controls the operating
pressure for safe operation of the Nailer.
Inspect the regulator before operation to
be sure it operates properly.
Lubricator .... The lubricator supplies an oil mist to the
Nailer.
Inspect the lubricator before operation to
be sure the supply of lubricant is
adequate.
Use Hitachi pneumatic tool lubricant.
Nailer Side
Lubricator
NEVER use oxygen or
other bottled gases.
Explosion may occur.
2
).
2
).
Regulator
Compressor Side
Filter