DC-Kit3
Observe the following safety instructions for the electrical connections:
A
NOTICE! Risk of short circuit!
• First, disconnect the 230 V external power supply to the caravan.
• Disconnect the earth connection to the supply battery.
• Disconnect the connection to the starter battery.
• If you have to feed cables through metal walls or other walls with
sharp edges, use ducts or tubes to prevent damage.
• Do not lay cables which are loose or bent next to electrically
conductive material (metal).
• Fasten the cables securely.
• Ensure the 12 V cables are especially well-protected.
• Check whether you need to fit any additional fuses.
• Do not pull on the cables.
• Do not lay the 230 V mains cable and the 12/24 V DC cable in the
same duct.
• Lay the cables so that they cannot be tripped over or damaged.
Observe the following instructions when selecting the location for installing the
components:
• Make sure the cables are of the correct length.
• Choose a well-ventilated installation location near the supply battery.
7.1
Preparing the installation
➤ Disconnect the following voltage supplies in the vehicle:
– Positive battery terminal
– External voltage supply
7.2
Installing components
➤ Install the ECL-102 charging current distributor.
➤ Install the MSI1812T inverter.
➤ Install the MCR9 remote control.
D
DANGER! Electrocution!
Only connect the battery once you have the completed all the
installation work and you are certain it has been done properly.
EN
Installing and connecting the DC kit
15