TECHNICAL SPECIFICATIONS
SYSTEM
Battery voltage
Nominal capacity 20H (C20)
Effect of the temperature on capacity
Self-discharge
Internal resistance
PERFORMANCE
Nominal capacity
20h (C20)
10h (C10)
5h (C5)
1h (C1)
Cycle (% of discharge)
20%
50%
80%
100%
Maximum charging current
Maximum discharge current
0,1 s
5 S
Continuous
Current of cold start cycle (CCA-EN)
MECHANICAL CARACTERISTICS
Connector technology
Shape of plates
Plate material
Separator
Electrolyte
Case material
Operating temperature
Dimensions (l x h x p)
Weight
UNIBAT
UNIBAT
80.12 AGM
100.12 AGM
12V
12V
80Ah
100Ah
< 5,8 mΩ
< 5 m Ω
80 Ah
100 Ah
74 Ah
95 Ah
67 Ah
87 Ah
43 Ah
64 Ah
32A
40A
1600A
1900A
640A
760A
240A
285A
630A
650A
M8 copper nickel-silver plated brass insert
High resistance polypropylene
368 x 219
368 x 219 x172
x172 mm
mm
27kg
29,5kg
www.uniteck.fr
UNIBAT
150.12 AGM
12V
150Ah
30°C : 105%
25°C : 103%
10°C : 95%
-10°C : 78%
1 months : 3%
3 months : 8%
6 months : 15%
< 3,1 m Ω
150 Ah
143Ah
131 Ah
98 Ah
2000 ~ 2500
900 ~ 1000
600 ~ 650
350 ~ 400
57A
2860A
1144A
430A
880A
Flat
Pure lead at 99,99%
AGM
Absorbed
-15°C ~ + 40°C
522 x 221 x
240 mm
43,5kg
EN
UNIBAT
220.12 AGM
12V
220Ah
< 2,5 m Ω
220 Ah
205 Ah
194 Ah
144 Ah
82A
4100A
1640A
615A
1120A
522 x 221 x 240
mm
58,5kg
29/46