Sae O-Ring Fitting Installation; Accessories And Service Kits; Airless Tip Selection - Speeflo PowrTwin 6900GH Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SAE O-Ring Fitting Installation

Steps 1 & 2:
Lubricate
Step 3:
Step 4:
Step 5:
Tighten nut
Hold
this part
stationay
Recess
gap
Cautions:
Avoid screwing fitting in too far.
No gap
Bent washer allows
for o-ring extrusion
Avoid leaving fitting too far out.
© Titan Tool Inc. All rights reserved.
Lubricate
1. Pull washer and o-
ring back as far as
possible.
2. Lubricate o-ring and
entrance port.
3. Screw fitting in until
washer pushes o-
ring into entrance
and sits flat against
port. (Do not
tighten! - only do this
step hand tight to
compress o-ring into
port!)
4. Back fitting out no
more than one
complete turn to
align as required.
5. Torque nut wrench
tight holding backup
on fitting. This
should expose a
recess gap behind
the nut which can
act as an indicator
that the fitting is
assembled correctly.
(This is a feature for
a specific version of
this fitting only -
which screws into
the cylinder head.
Other fittings, as the
ones which attach to
the hydraulic pump,
assemble the same
but may not have
the indicator.)
O-ring cut on
thread

Accessories and Service Kits

These items may be purchased separately from your local
Speeflo distributor.
Part #
Description
103-826
5 Gal. Siphon Hose Assembly w/Rock Catcher
1" x 4.5'
103-827
55 Gal. Siphon Hose Assembly w/Rock Catcher
1" x 6.5'
103-627
Rock Catcher
930-005
Paint Filter Element, 5 Mesh (for multicolors
and heavy materials)
930-006
Paint Filter Element, 50 Mesh (for latex and
normal architectural materials)
930-007
Paint Filter Elements, 100 Mesh (for stains,
lacquers and fine materials)
520-050
SGX-20 G, T, and 1/4" Hose Kit
520-051
SGX-20 G, T, and 3/8" Hose Kit
101-208
Grounding Clamp
101-212
Grounding Wire, 12 Gauge x 25'
700-925
Piston Lube
430-362
Coolflo™ Hydraulic Fluid, 1 Quart
430-361
Coolflo™ Hydraulic Fluid, 1 Gallon
143-050
Fluid Section Service Kit — Minor
930-050
Filter Service Kit
944-050
Bleed Valve Service Kit
975-212
2-Gun Manifold with Ball Valves, 1/4"
975-213
3-Gun Manifold with Ball Valves, 1/4"
975-312
2-Gun Manifold with Ball Valves, 3/8"
975-313
3-Gun Manifold with Ball Valves, 3/8"

Airless Tip Selection

Tips are selected by the orifice size and fan width. The proper
selection is determined by the fan width required for a specific
job and by the orifice size that will supply the desired amount
of fluid and accomplish proper atomization.
For light viscosity fluids, smaller orifice tips generally are
desired. For heavier viscosity materials, larger orifice tips are
preferred. Please refer to the chart below.
NOTE: Do not exceed the pump's recommended tip
size.
The following chart indicates the most common sizes and the
appropriate materials to be sprayed.
Tip Size
Spray Material
.011 – .013
Laquers and stains
.015 – .019
Oil and latex
.021 – .026
Heavy bodied latex and blockfillers
Fan widths measuring 8" to 12" (20 to 30 cm) are most
preferred because they offer more control while spraying and
are less likely to plug.
27
Español
Français
Filter Type
100 mesh filter
50 mesh filter
5 mesh filter
English

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

448-894448-897448-899448-898

Tabla de contenido