Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
10.10 Optional: Connect the second sensor.
j ... adapter cable for sensors
k ... door contact
l ... yellow
m ... brown
10.11 Optional: Connect the third sensor.
j ... adapter cable for sensors
n ... trigger device for disabled person
o ... white
p ... green (for Y-sensor distributor 2/3, use "yellow" wire colour)
10.12 Connect the electronic module (K) to the second electrical T-distributor (c).
10.13 Place the electrical T-distributors into the cistern.
Install the cover plate
10.14 Insert the screws (q) into the tabs (r).
10.15 Turn the screws by 90°.
10.16 Fit the frame (s) and screw it down.
10.17 Connect the piezo button to the electronic module.
10.18 Pull the protective foil off the cover plate.
10.19 Seal the cover plate, e.g. with Chromol (not part of the delivery scope,
see Accessories
10.20 Fit the cover plate (t) and screw it down.

11. Function

11.1 Press the piezo button.
• The flush system will be activated.
• Flushing will stop automatically.
An automatic hygiene flushing function after 24 hours of non-use has been factory-set.
The automatic hygiene flushing function can be switched off or on with the touch
code (see
Chapter
Function with door contact (optional):
Pre-flushing takes place for 1 second when the door is closed.
There is a minimum time interval of 5 minutes between two pre-flushes.
If the door remains locked for more than one minute and the sensor or trigger for the
disabled is not activated during this time, the flush will be automatically activated
when the door is unlocked.
Chapter
15).
12.).
- 7 -

Publicidad

Tabla de contenido
loading

Tabla de contenido