Functions Indication Table - Ideal 61-327 Manual De Operación Y Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Functions Indication Table

Function
Description
LCD
One LCD. Displays a "-" symbol for all negative readings, displays "AC" for
alternating current or "DC" for direct current.
LCD
White backlight. The backlight will automatically power off after 5 minutes
Backlight
of inactivated
High
1) Only applicable to ACV / DCV
Voltage
2) For ACV and DCV, when voltages in excess of 30V is measured or the
Alarm
measured voltage is over limit, then the high voltage alarm symbol "
appears on the screen display, simultaneously the LED remains RED and
beeping lasts for 1 second then becomes silent during measurement.
Regular
1) When turning the dial switch to any setting position except OFF, the buzzer
Prompt
will beep one time and the NCV LED flashes one time.
2) When the button selection is valid, the buzzer will beep one time; When the
button is invalid, the buzzer will beep twice.
3) About 1 minute before the automatic shutdown, the buzzer will beep 5
times continuously, and 1 long beep before the unit shuts down.
4) When the automatic shutdown function is canceled, the buzzer will beep 5
times when it reaches the APO time setting.
Over Range
LCD displays "OL" when over range is encountered.
Indication
Low Battery
When the battery voltage < 3.6 ±0.2V, the low battery indication '
Indication
displayed on the screen and the meter will still work normally. When the
battery voltage drops to less than 3.1 ±0.2V, "bAtt" is displayed for 5 seconds
then shuts off. When the battery voltage is less than 2.3V, accuracy is no
longer assured.
APO
The unit will be automatically power off after 30 minutes of inactivity and
enter the low-power state. Current draw is approx. ≤50 micro A.
Restore
All the buttons can wake up the unit, rotate the dial switch to any setting
APO
except OFF to wake it up.
Disable
Pressing the "HOLD" key while turning on the unit on at the same time, will
Auto Power
cancel the auto shutdown function. Buzzer will beep 5 times and the LCD will
Off Function
not display the "APO" symbol.
Mechanical
Single Injection Molding with rubber boot.
Housing
."
' is
18

Publicidad

Tabla de contenido
loading

Tabla de contenido