EN
15 COMMISSIONING
15.1
Preliminary checks
Commissioning of the Brava One boiler must be carried out by
professionally qualified Personnel after which the boiler can
operate automatically. It may however be necessary for the
User to start the appliance autonomously without involving a
technician: for example, after a holiday . In these cases certain
checks and the following operations must be carried:
– check that the gas isolation and water system valves are
open
– using a pressure gauge (1), check that the heating system
pressure when cold is 1-1.2 bar . If this is not the case, open
the filling valve (2) and restore the heating system pressure
until the pressure gauge (1) shows a reading of 1-1.2 bar
– close the filling valve (2).
2
15.2
Ignition
After having carried out the preliminary checks, perform the
following to start the boiler:
– set the main system switch to "ON"
ON
– on the display, check that the operating mode on the display
is "SUMMER"
l
and if necessary select it by pressing and
holding the button
s
for at least 1 second. the value of the
delivery sensor detected at that moment will appear on the
display
1
Fig. 1
Fig. 2
– open one or more than one hot water tap. The boiler will
work at maximum power until the taps are closed.
Once the boiler has been commissioned in "SUMMER mo-
de"
l
"WINTER mode"
n
holding the button
s
for at least 1 second. the value of the
heating water temperature detected at that moment will ap-
pear on the display. In this case it is necessary to adjust the air
thermostat/s to the required temperature or if the system has
a chrono-thermostat, check that this is "active" and adjusted.
15.3
Adjusting the delivery temperature
If the boiler delivery temperature is to be increased or decre-
ased it is possible to act on the
rather than having to modify the specific parameters. The
temperature can be set to between 20 and 80°C.
15.4
Adjusting the domestic hot water
temperature
If the domestic hot water temperature is to be increased or
decreased, act on the
r
knob on the control panel. The tem-
perature can be set to between 10 and 60°C.
can be selected by pressing and
t
knob on the control panel
Fig. 3
Fig. 4
19