Ho w
the air conditioner w or k s
AUTO operation
When you set the air conditioner in AUTO mode,
it will automatically select cooling, heating(cooling
/heating models only), or fan only operation
depending on what temperature you have selected
and the room temperature.
The air conditioner will control room temperature
automatically round the temperature point set by
you.
If the AUTO mode is uncomfortable, you can
select desired conditions manually.
SLEEP operation
When you push SLEEP button on remote controller
during cooling, heating(cooling only type without),
or AUTO operation , the air conditioner will
automatically increase (cooling) or decrease
(heating) 1℃ per hour.
The set temperature will be steady 2 hours later.
And the air conditioner will be timer off in 7 hours.
The fan speed will be automatically controlled.
This feature can maintain the most comfortable
temperature and save more energy for you.
Cooling mode:
setting
T+1(℃)
T(℃)
1st hour
2nd hour
Heating mode:
setting
T-2(℃)
T(℃)
1st hour
2nd hour
The sleep mode will last for 7 hours ,and then stop automatically.
Airflo w
direction control
Adjust the air flow direction properly otherwise, it
might cause discomfort or cause uneven room
temperatures.
Adjust the horizontal louver using the remote
controller.
Adjust the vertical louver manually.
To set the vertical air flow(Up--Down) direction
Perform this function while the unit is in operation.
Use the remote controller to adjust the air flow
direction. The horizontal louver can be moved at
a range for each press, or swing up and down
automatically. Please refer to the REMOTE
CONTROLLER OPERATION MANUAL
To set the horizontal air flow direction (left - right)
Move the vertical louver manually to adjust the air flow
in the direction you prefer.
IMPORTANT
:Beforeadjustingtheverticallouvers,the
supply power must be disconnected.
For some models, the vertical louver can be adjusted
by using the remote controller. Please refer to the
,,
REMOTE CONTROLLER OPERATION MANUAL
for details.
DESCRIPTION AND OPERATING INSTRUCTIONS
T+2(℃)
Keep running for
another 5 hours
T-4(℃)
Keep running for
another 5 hours
,,
,,
for details.
stop
automatically
stop
automatically
Do not operate the air conditioner for long periods with
the air flow direction set downward in cooling or
dehumidifying mode. Otherwise, condensation may
occur on the surface of the horizontal louver causing
moisture to drop on to the floor or on furnishings.
Do not move the horizontal louver manually unless it is
necessary. Always use the remote controller.
When the air conditioner is started immediately after it
was stopped, the horizontal louver might not move for
approximately 10 seconds.
Open angle of the horizontal louver should not be set
too small, as COOLING or HEATING performance may
be impaired due to too restricted air flow area.
Do not operate unit with horizontal louver in closed
position.
When the air conditioner is connected to power (initial
power), the horizontal louver may generate a sound for
10 seconds, this is a normal operation.
,,
47