Troubleshooting for wireless activation function
Before asking for repairs, conduct your own inspection first. If you find a problem that is not explained in the manual,
do not attempt to dismantle the tool. Instead, ask Makita Authorized Service Centers, always using Makita replace-
ment parts for repairs.
State of abnormality
The wireless activation lamp does
not light/blink.
Cannot finish tool registration / can-
celling tool registration successfully.
State of abnormality
The cleaner does not run along with
the switch operation of the tool.
Probable cause (malfunction)
The wireless unit is not installed into the
cleaner and/or the tool.
The wireless unit is improperly installed
into the cleaner and/or the tool.
The terminal of the wireless unit and/or
the slot is dirty.
The wireless activation button on the
tool have not been pushed.
The stand-by switch on the cleaner is
not set to " I (ON)".
No power supply
The wireless unit is not installed into the
cleaner and/or the tool.
The wireless unit is improperly installed
into the cleaner and/or the tool.
The terminal of the wireless unit and/or
the slot is dirty.
The stand-by switch on the cleaner is
not set to " I (ON)".
No power supply
Incorrect operation
The tool and cleaner are away from
each other (out of the transmission
range).
Before finishing the tool registration/cancellation;
- the switch trigger on the tool is pulled or;
- the cleaner's switch to start vacuuming
is pushed.
The tool registration procedures for the
tool or the cleaner has not been finished.
Radio disturbance by other appliances
which generate high-intensity radio waves.
Probable cause (malfunction)
The wireless unit is not installed into the
cleaner and/or the tool.
The wireless unit is improperly installed
into the cleaner and/or the tool.
The terminal of the wireless unit and/or
the slot is dirty.
The wireless activation button on the
tool have not been pushed.
The stand-by switch on the cleaner is
not set to " I (ON)".
More than 10 tools are registered to
the cleaner.
The cleaner erased all tool registrations.
No power supply
The tool and cleaner are away from
each other (out of the transmission
range).
Radio disturbance by other appliances
which generate high-intensity radio waves.
21 ENGLISH
Remedy
Install the wireless unit correctly.
Gently wipe off dust and dirt on the terminal of the wire-
less unit and clean the slot of the cleaner and/or the tool.
Push the wireless activation button on the tool briefly. Make
sure that the wireless activation lamp is blinking in blue.
Set the stand-by switch on the cleaner to " I (ON)".
Supply the power to the tool and the cleaner.
Install the wireless unit correctly.
Gently wipe off dust and dirt on the terminal of the wire-
less unit and clean the slot of the cleaner and/or the tool.
Set the stand-by switch on the cleaner to " I (ON)".
Supply the power to the tool and the cleaner.
Push the wireless activation button briefly and perform
the tool registration/cancellation procedures again.
Get the tool and the cleaner closer to each other. The
maximum transmission distance is approximately 10 m
however it may vary according to the circumstances.
Push the wireless activation button briefly and
perform the tool registration/cancellation procedures
again.
Perform the tool registration procedures for the tool
and the cleaner at the same timing.
Keep the tool and the cleaner away from the appli-
ances such as Wi-Fi devices and microwave ovens.
Remedy
Install the wireless unit correctly.
Gently wipe off dust and dirt on the terminal of the wire-
less unit and clean the slot of the cleaner and/or the tool.
Push the wireless activation button on the tool briefly. Make
sure that the wireless activation lamp is blinking in blue.
Set the stand-by switch on the cleaner to " I (ON)".
Perform the tool registration again.
If more than 10 tools are registered to the cleaner, the
tool registered earliest will be cancelled automatically.
Perform the tool registration again.
Supply the power to the tool and the cleaner.
Get the tool and the cleaner closer to each other. The
maximum transmission distance is approximately 10 m
however it may vary according to the circumstances.
Keep the tool and the cleaner away from the appli-
ances such as Wi-Fi devices and microwave ovens.