SYMBOL DEFINITIONS

Class II electrical protection-
double insulated
Data port input/output
Next item on LCD display
Previous item on LCD display
Increase value on LCD
display
Decrease value on LCD
display
The device contains electrical and/or electronic equipment that must be recycled per EU Directive 2012/19/EU -
Waste Electrical and Electronic Equipment (WEEE)

IMPORTANT SAFEGUARDS

READ ALL INSTRUCTIONS BEFORE USING
THIS DEVICE.
SAVE THESE INSTRUCTIONS.
DANGER
Electric Shock Hazard – Do not use while bathing.
Electric Shock Hazard – Do not immerse this device into water or any other liquid.
Electric Shock Hazard – Do not attempt to open or remove the cabinet. There are no user-serviceable internal
components. If service is required, return the product to your home care provider. Opening or tampering with the
product will void the warranty.
WARNING
The DeVilbiss IntelliPAP should be used only with masks recommended by DeVilbiss, your physician or respiratory
therapist.
To avoid rebreathing of exhaled air, do not use a CPAP mask unless the device is turned on and providing a supply
of air. Venting in the mask should never be blocked. When the device is turned on and providing a fresh supply of
air, exhaled air is flushed out of the mask vent. However, when the device is not operating, exhaled air may be
rebreathed. Rebreathing of exhaled air for longer than several minutes can in some circumstances lead to
suffocation. This warning applies to most CPAP devices.
The DeVilbiss IntelliPAP is not a life support device and may stop operating with certain device faults or with a power
failure. It is intended to be used on spontaneously breathing individuals weighing 66 lbs/30 Kg or greater.
To avoid electric shock, always unplug power cord from wall outlet power source when performing cleaning.
Use only accessories recommended by DeVilbiss.
Always remove the water chamber from the optional humidifier cradle before filling.
If water has spilled onto the humidifier cradle or it has been submerged into water, unplug power cord from power
source immediately. Allow device to dry completely before use.
Never block air openings of the humidifier cradle or chamber. Do not insert objects into any openings or tubes.
For proper operation, place system on a flat, sturdy, level surface.
The optional humidifier is intended for single-patient use only.
If the system is placed on the floor, do not position it where it may be stepped on when getting out of bed.
CAUTION
The circular data port connector located on the back of the IntelliPAP is used to attach accessories to the device.
The connector must only be used with accessories approved for use by DeVilbiss. Do not attempt to attach any other
device to this connector as it may damage the CPAP or the accessory device.
Never rinse or place the device in water. Never allow liquids to get into or around any of the ports, switches or air
EN - 4
Locked
Unlocked
IPX1 Drip-proof, vertical
DC input: 12 VDC, center pin
positive
Attention, consult
accompanying documents
Type BF equipment-applied
part
Standby-turns blower on/off
Heat
100-240 VAC input 50/60 Hz
Delay-starts the delay cycle
Manufacturer
A-DV56